36
8.8 2011 Ozonator Not Working
Diagnostic Tools:
Clamp-on Ammeter, Voltmeter
Suggested Spare Parts:
Ozonator, Circuit Board, Control Panel
Standard Troubleshooting Approach
Refer to pages 50-53 for testing points.
This applies to 2011-2013 J300 Models not 2014+
Turn power to hot tub off and on.
Wait approximately two minutes
for filter cycle to begin and turn
on the circulation pump and
ozonator (J-LX, J300 and J200
with circ pump Models) or Pump
1 and ozonator (J200 without a
circulation pump.
DO NOT press either JETS
button at this time or ozonator
will shut off! Is filter cycle 1
running?
Is 120 VAC* or 240 VAC present
at circuit board ozone outputs?
Test points 16 and 17, See pages
*Convertible J-210, J-315, J-325
models only.
Is there a faint buzzing sound
coming from the ozonator’s
internal high voltage arching
chamber? Or is there current
draw from the ozonator (≈ 0.1
Amp)? Check with clamp-on
ammeter.
A faint buzzing sound and/or
current draw is proof that the
ozonator is working.
Read steps outlined above to
ensure customer understands
ozone logic.
Replace ozonator.
Replace circuit board.
Replace control panel.
Replace circuit board
Turn power off, plug
in spare control panel,
then turn power on. Wait
approximately 2 minutes
for filter cycle to begin. Is
filter cycle running?
No
Yes
No
Yes
Yes
No
Yes
No
DANGER: Electrical Shock Hazard Exists!
High Voltage Present on Circuit Board. Use
Extreme Caution while Servicing Circuit Board.
O
3