SPECIFICATIONS
OPERATING PARAMETERS
Delta HT-E-SEER
Operating Capacity:
Racks per Hour
20
Dishes per Hour
500
Glasses per Hour
720
Tank Capacity (Gallons):
Wash Tank
3
Rinse Tank
1.66
Always refer to the machine data plate for specific electrical and water
requirements. The material provided on this page is for reference only and
is subject to change without notice.
Cycle Times (Seconds):
Water Temperatures (°F):
Minimum Wash Temperature
155
Minimum Rinse Temperature
180
Minimum Incoming Water Temperature
40
Maximum Incoming Water Temperature
90
Other Water Requirements:
Water Flow Pressure (PSI)
10
Flow Rate Minimum (GPM)
4.33
Water Line Size (NPT)
3/4" Male GHT
Connect to true 1/2" ID Line
Drain Line Size (NPT)
1" ID
1 3/8" OD
Connect to MIN 1 1/2" Drain with
Air-gap
Gallons per Hour (GPH)
13
Gallons per Rack (GPR)
0.65
NOTICE
i
Incoming water is from a
"cold" water line.
Cycle I
Wash 80
Rinse 9
Dwell 11
SEER 45
Total 145
Cycle II
Wash 148
Rinse 9
Dwell 11
SEER 45
Total 213
Cycle III
Wash 248
Rinse 9
Dwell 11
SEER 45
Total 313