Jackson WWS, Inc.
P.O. Box 1060
Barbourville, KY 40906
888-800-5672
INSTRUCTIONS FOR TEMPSTAR DRAIN QUENCH KIT
WARNING:
•
This kit should be installed only by qualified service personnel to reduce the risk of
electric shock, serious injury or fire. A plumbing permit and the services of a licensed
plumber and electrician may be required in some areas.
•
Turn off the power supply and place the dishwasher disconnect (if applicable) in the
off position. Lockout/Tag out to prevent the power supply from being turned back on
inadvertently.
•
Failure to install this kit within the guidelines may adversely affect safety,
performance, component life and warranty coverage.
Tools Required:
•
Pipe Wrench
•
Adjustable Wrench
•
5/16” Nut Driver
•
3/8” Nut Driver or Wrench
•
Phillips Screwdriver
•
Pipe Thread Sealant Tape or Pipe Dope
•
Needle Nose Pliers
Parts Included:
Assembly 05700-004-14-96
INDEX
NO.
DESCRIPTION
PART NUMBER
QTY
1
TEE, 1-1/2 BRASS
04730-011-69-93
1
2
NIPPLE, 1-1/2 BRASS CLOSE
04730-207-40-00
2
3
REDUCER, 1-1/2 X ¼ HEX BRASS
04730-002-55-76
1
4
UNION, ¼ MODIFIED
05700-001-16-52
1
VIEW OF
COMPLETE
PLUMBING
ASSEMBLY
07610-004-07-99 1