![Jackson Labs PHASE STATION 53100A Скачать руководство пользователя страница 77](http://html1.mh-extra.com/html/jackson-labs/phase-station-53100a/phase-station-53100a_user-manual_3161392077.webp)
PhaseStation 53100A User’s Manual V1.04 25-Apr-2022
77
Export ASCII phase data (
x
)
This command is supported only when viewing the selected plot’s phase record
contents using
Measurement
→
Phase difference (
p
)
or
Measurement
→
Frequency-
difference (
f
)
. It will save an ASCII text file containing phase difference data in seconds,
one entry per line, at 16 digits of precision to the right of the decimal point.
If a selected or zoomed area has been defined by dragging with the mouse, only that
portion of the phase record will be exported.
By default, the exported phase data will be saved with the suffix .CSV for ease of reading
into Excel and other spreadsheets. Exported data may be re-imported into TimeLab, if
necessary, by the
File
→
Import ASCII phase or frequency data
command. Select “All
files” as the file type if the data was not exported with the suffixes .TXT or .DAT, then
select
Phase difference (sec)
as the file data type.
Optionally, each sample in the ASCII phase data file can be timestamped with its
absolute MJD or the number of elapsed seconds since the beginning of the phase
record.
Export ASCII frequency data (
X
)
This command is supported only when viewing the selected plot’s phase record
contents using
Measurement
→
Phase difference (
p
)
or
Measurement
→
Frequency-
difference (
f
)
. It will save an ASCII text file containing absolute frequency readings in
hertz, one entry per line, at 16 digits of precision to the right of the decimal point.
If a selected or zoomed area has been defined by dragging with the mouse, only that
portion of the phase record will be exported.
By default, the exported frequency readings will be saved with the suffix .CSV for ease of
reading into Excel and other spreadsheets. Exported data may be re-imported into
TimeLab, if necessary, by the
File
→
Import ASCII phase or frequency data
command.
Select “All files” as the file type if the data was not exported with the suffixes .TXT or
.DAT, then select
Frequency (Hz)
as the file data type.
Optionally, each sample in the ASCII phase data file can be timestamped with its
absolute MJD or the number of elapsed seconds since the beginning of the phase
record.
Содержание PHASE STATION 53100A
Страница 1: ...TM 53100A Phase Noise Test Set User s Manual Revision 1 04 April 25 2022...
Страница 16: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 16...
Страница 18: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 18...
Страница 20: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 20...
Страница 30: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 30...
Страница 36: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 36...
Страница 42: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 42...
Страница 64: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 64...
Страница 74: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 74...
Страница 104: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 104...
Страница 116: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 116...
Страница 122: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 122...
Страница 130: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 130...
Страница 140: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 140...
Страница 143: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 143 Figure 66 5 MHz residual phase noise and AM noise...
Страница 214: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 214...
Страница 215: ...PhaseStation 53100A User s Manual V1 04 25 Apr 2022 215 Appendix Legal and regulatory notices...