5
/
8
3.6.2 Technicians parameters
param
eters
descriptions
Factory
value
range
num
ber
descriptions
Factory
value
range
P44
Delaying time when
touching the front pedal
0
:
off
1-300
:
on
0
0-300
P68
Maximum speed setting (r/min)
3700
200-500
0
P45
Working time of presser
foot every period(ms)
1
1-10
P69
Stich quantityby testing the top
thread
5
0-100
P46
Closing time of presser
foot every period (ms)
2
1-10
P70
Presser foot position setting
800
0-4095
P47
Reverse pulling after
trimming
360
200-36
0
P71
Slowly presser foot
125
100-150
P48
Back sewing magnet
protection time (s)
10
1-60
P72
Initial position when pressing
the pedal
400
0-4095
P49
Trimming time(r/min)
250
100-50
0
P73
Ending position of pedal under
low speed
700
0-4095
P50
Duration of presser foot
magnet to the power
fullest (ms)
150
100-50
0
P74
Maximum value of pedal
4000
0-4095
P51
Working time of presser
foot magnet every period
(ms)
3
1-10
P75
Mid position of pedal
1650
0-4095
P52
Presser foot delaying
time (ms)
200
100-50
0
P76
Back sewing magnet from
starting to the fullest time (ms)
60
1-200
P08
Slow starting sewing
stitches
1
1-9
P33
Tread tension magnet period
(from beginning to full energy)
6
1-10
P09
Slow starting sewing
switch
0
:
off
1
:
on
1
0-1
P34
Multi-phase mode
0:off
1:on
0
0-1
P10
W sewing stitch
(
sucking
)
27
1-120
P35
Thread tension switch
1
0-1
P11
W sewing stich
(
releasing
)
18
1-120
P36
Angle of finishing testing the
top thread
25
1-360
P12
Half stitch delaying
time(ms)
150
1-180
P37
Closing time of tension post
period
4
1-10
P13
One stitch delaying
time(ms)
180
150-25
0
P38
Thread trimer
0: off
1
:
on
1
0-1
P14
Adding stitch sewing
speed(r/min)
200
100-50
0
P39
Presser foot switch during
sewing
0: off
1
:
on
0
0-1
P15
Adding stitch type
0
:
by time
1
:
half
stitch
2
:
one stitch
0
0-2
P40
Presser foot switch after
trimming
0:off
1:on
0
0-1
P18
Front safty sewing stitch
27
1 - 120
P41
Stitch number
1
1-50
P19
Back safty sewing stitch
18
1 - 120
P42
Stitch number calculation
9999
1-9999
P21
Manual back sewing
speed (r/min)
5000
200-50
00
P43
Stitch counting number
0
:
off
1
:
up
2
:
down
3
:
alarm and stop when arrive the
highest point
4
:
alarm and stop when arrive
the lowest point
5
:
alarm and run when arrive
the highest point
6
:
alarm and run when arrive
the lowest point
0
0-6
P22
Value of back sewing
fuction when adding
stitch
8
0-9999