background image

Model 37202-Series

Model 37202-Series

ELECTRIC BILGE PUMPS

FEATURES

Pumpgard Inlet Strainer Supplied With Pump

Self-Priming

Diaphragm Design Allows Dry Running

Built-in Hydraulic Pulsation Dampener

Corrosion Resistant Materials Throughout
for Sea Water Service

Meets USCG Electrical Regulation 183.410
and ISO 8846 Marine for Ignition Protection.

N.M.M.A. Type Accepted

SPECIFICATIONS

Open Flow:

4.5 GPM

Vert. Dry Suction Lift:

7 feet

Ports:

3/4

" Slip-on Hose

Weight:

5.5 lb (2,5 kg)

INSTALLATION

MOUNTING

Mount upright in a dry location (above highest bilge water
level) on a solid surface. Mounting screws should be
tightened only enough to slightly compress grommets.
Overtightened screws will reduce cushioning effect of
mounts and may cause excessive noise.

PLUMBING

For intake and discharge, use 3/4" ID non-collapsible
hose. Keep intake and discharge lines free of kinks and
restrictions. To protect pump from debris, install the 3/4"
in-line strainer (Model 36200-0000) in the intake line
from the bilge. Use a 3/4" thru-hull fitting for discharge
located well above the waterline at all angles of heel.

WIRING

Wire pump in a circuit independent of all other electrical
fixtures. Use stranded copper wire. Install fuse in 
positive circuit. See table for recommended wire and fuse
size. See diagram for wiring connections. Use a
10 amp-rated switch (3-way switch Model 44960-0001).
After installation, it is recommended that voltage be
checked at the motor terminals with motor operating
under full load. Be sure measured voltage is not less than
11 volts on a 12 volt system with a fully charged battery

.

STANDARD MODELS

Nominal

Fuse

Model

Voltage

Current

Size

37202-0000

12 Vdc

7.5 AMP

10 AMP

37202-0010

24 Vdc

6.5 AMP

10 AMP

MAINTENANCE

LUBRICATION:

Check connecting rod bearing annually

and add chassis lube as needed. No other lubrication of the
pump is required.

WINTER STORAGE:

The pump must be completely

drained, hoses removed and pump run until all water is
expelled.

WIRING TABLE

Wire Length Between

Battery and Motor

Wire Gauge

1 - 25 feet

12 AWG

25 - 50 feet

10 AWG

BATTERY

FUSE

MANUAL

OFF

AUTOMATIC

PUMP

3-WAY SWITCH
44960-0001

Automatic Bilge Switch
Model 34875-Series or
Any JABSCO Float Switch

WIRING DIAGRAM FOR AUTOMATIC OPERATION

-

+

DIMENSIONAL DRAWING

Отзывы: