background image

Model 37010-Series

M

o

d

e

l 3

7

0

1

0

-S

e

rie

s

ELECTRIC MARINE TOI LET 
Push Button Operation

FEATURES

• White Vitreous China Bowl Available in Two Sizes
• Baked enamel seat & cover - 

soft close seat option available on regular bowl models

• Flexible Impeller Flush Pump
• Permanent Magnet Type Motor, Fully Enclosed, with

Stainless Steel Shaft

• High Capacity Waste Macerator and Bowl discharge Pump
• Built-in Back Flow Preventer

V

Corrosion resistant material for marine use

ARIATIONS

MODEL NUMBER 

DESCRIPTION

37010-3092 

 

Compact Bowl 12V 

37010-3094 

 

Compact Bowl 24V 

  

37010-4092 

 

Regular Bowl 12V 

37010-4192 

 

Regular Bowl 12V, Soft Close Seat/Lid 

37010-4094 

 

Regular Bowl 24V 

37010-4194 

 

Regular Bowl 24V, Soft Close Seat/Lid

INSTALLATION

The Jabsco electric toilet may be installed above or below

the waterline. Flush pump is self-priming with a vertical lift

up  to  4  feet;  discharge  macerator  pump  can  operate

against a vertical head up to 4 feet (1.2m).
Inlet and outlet seacocks should be easily accessible and

be positive shut off valves. If seacocks cannot be con ve -

nient ly operated from toilet location, install suitable shut off

valves for inlet and discharge connections.
Base assembly may be moved 90° to accommodate con -

nec tions and provide accessibility for servicing.
Surface where toilet is mounted should be flat to prevent

distortion of toilet base.
PLUMBING CONNECTIONS - Connect inlet hose using

3/4" (19mm) ID hose. Make sure all inlet connec-tions 

are airtight and free of sharp bends or restrictions.

 

Do  not  connect  the  toilet  to  the  vessels

potable water for its source of supply. To do so can result in

contamination of potable water supply. If fresh water is pre-

ferred for flushing, provide a separate fresh water tank to

supply water to the toilet only.
DO NOT CONNECT INLET HOSE TO A PRESSURIZED

WATER SYSTEM.

Flood hazard.   If toilet is installed below the 

waterline or may be below the waterline at any 

angle of heel or trim, it must be installed with 

properly positioned vented loops.  Failure to do 

so can result in flooding which can cause loss 

of property and life.

WARNING

!

CAUTION

!

Connect 1" (25mm) or 1-1/2" (38mm) hose to discharge 

hose to discharge port (Adaptor98023-0080 is included to 

convert discharge port to 1-1/2"ID hose), and make 

suitable connection to holding tank orother discharge 

system. Avoid sharp bends or restrictions.For above 

waterline installations, a check valve may haveto be instal-

led in the flush water intake line to ensure rapidpump 

priming. To retain water in bowl, make a loop in thedischar-

ge line about 8 inches (200mm) above base of bowl.

If the toilet is, or can be, below waterline at any normal(in-

cluding static) attitude of vessel heel and/or trim, a 3/4" 

(19mm) Vented Loop Fitting must be installed in the 

length of hoseconnecting the flushing pump to the inlet 

seacock. TheVented Loop Fitting must be positioned so it 

remains at least 8" (200mm)* above the waterline at all 

angles of heel and trim.In some installations when a 

vented loop is installed in theintake hose, the flushing 

pump primeability and flow char-acteristics are reduced 

and may adversely affect toiletfunction. To restore pump 

performance, connect a solenoidvalve (Jabsco No. 

37068-0000) to the vent air inlet to inter-rupt the air 

supply during the flush cycle. The brass port ofthe 

solenoid valve (remove plastic filter if attached)shouldbe 

connected to the vent inlet with 3/16" hose and thesole-

noid wired in parallel with the toilet motor. See diagram 

below.

Содержание 37010-4092

Страница 1: ... supply If fresh water is pre ferred for flushing provide a separate fresh water tank to supply water to the toilet only DO NOT CONNECT INLET HOSE TO A PRESSURIZED WATER SYSTEM Flood hazard If toilet is installed below the waterline or may be below the waterline at any angle of heel or trim it must be installed with properly positioned vented loops Failure to do so can result in flooding which can...

Страница 2: ...ds until all water is pumped out After long periods of non use toilet and pump may dry out To ease initial start up put about one quart of water in bowl and let stand awhile before initial use DISASSEMBLY Disconnect pumping inlet and discharge hoses Remove four screws Key No 25 pull out complete motor pump and macerator assembly If assembly does not slide out easily push forward and pull back shar...

Страница 3: ...ock Nut 1 37056 1000 15 Macerator Housing 1 37014 0000 16 Centrifugal Impeller 1 37006 0000 17 Set Screw 1 18753 0492 18 O ring 1 43990 0066 19 Sealing Sleeve 1 37036 1000 20 Screw 2 91009 0096 21 Screw 2 91010 0130 22 Washer Fiber 2 35445 0000 23 Wearplate Kit 1 37018 0000 24 Lock Washer 10 Stainless Kit 4 25 Screw 4 91027 0011 26 Gasket 1 12558 0000 27 Flexible Impeller 1 6303 0003 28 Body 1 125...

Страница 4: ... is a trademark of Xylem Inc or one of its subsidiaries 43000 0789 Rev B 43000 0612 Rev D 12 2017 THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST www ittflowcontrol com Copyright 2010 ITT Corporation Printed in U S A All Rights Reserved Form 43000 0612 Rev A 11 2010 1 Dia 25 4 102 6 152 D Overall Width C G E F 5 ...

Отзывы: