background image

www.PumpAgents.com

Models 30570-2XXX, 30570-3XXX

30570-4XXX, 30570-5XXX

Models 30570-2, 3, 4, 5XXX

SELF-PRIMING PUMPS

FEATURES

Pump Type: 30570-2XXX Pump Head

30570-3XXX Pump Head
30570-4XXX Close Coupled
30570-5XXX Close Coupled

Body: 

316 Stainless Steel

Impeller:

Neoprene or EPDM

Shaft Seal:

Mechanical; Carbon-on-Ceramic or
Tungsten Carbide; Nitrile

Ports:

1-1/2" ACME Threads with Bevel Seat or
Clamp Type

Shaft:

316 Stainless Steel

Motor:

230/460 Vac, 3 Phase, 60Hz, 5 HP
1750 RPM, TEFC, C-Face, 184 TC Frame

Weight:

30570-2XXX 30.0 lb (18.6 kg) Approx.
30570-3XXX 30.0 lb (18.6 kg) Approx.
30570-4XXX 93.5 lb (42.5 kg) Approx.
30570-5XXX 93.5 lb (42. kg) Approx.

VARIATIONS AVAILABLE

Model

Description

30570-2005

Standard Pressure, Neoprene Impeller,

30570-4005

Carbon Seal, ACME Ports

30570-2105

Standard Pressure, Neoprene Impeller, 

30570-4105

Tungsten Carbide Seal, ACME Ports

30570-3005

Standard Pressure, Neoprene Impeller, 

30570-5005

Carbon Seal, Clamp Ports

30570-3105

Standard Pressure, Neoprene Impeller,

30570-5105

Tungsten Carbide Seal, Clamp Ports

APPLICATIONS

DAIRY: Transfer and processing of raw milk, cream, milk
whey, buttermilk, condensed milk.
FOODS: Processing of eggs, sugar liquors, brines, catsup,
chocolate, glaze, gelatin, honey, jams, jellies, mayonnaise,
molasses, mustard, pickle relish, vinegar, water, yeast
slurries, syrups, liquids containing solids in suspension
such as chopped tomatoes, nuts, peanut butter.
BEVERAGE: Circulating and transferring alcohols, beers,
brewery slop, cider, distillery wort, extracts, flavors, juice,
mash, soft drink syrups, wines.
PHARMACEUTICAL:  Moving medicines, cosmetics,
process chemicals, lotions, preparations, filtering
solutions, used as a filling line supply pump.

OPERATING INSTRUCTIONS

1.

INSTALLATION – Pump may be mounted in any
position. The rotation of the pump shaft determines
the location of the pump's intake and discharge ports.
(Refer to dimensional drawing.) Pump is normally
assembled at factory for clockwise rotation looking at
end cover. If counterclockwise rotation is desired,
follow steps 1 and 2 of disassembly and step 9 of
assembly instructions to change direction of impeller
blade deflection under cam.

2.

MOTOR SELECTION – Pump Head is designed to fit
a 184 TC Frame NEMA C-Face Motor. Motor should
be rated 5 horsepower at 1750 RPM with a service
factor of one. Due to high bearing loads, motor should
be ball bearing equipped with the front bearing locked
against axial movement. Motor should be capacitor
start and foot mounted.

3.

SPEEDS – 100 RPM to the maximum shown in the
performance curves. For longer pump life, operate at
lowest possible speeds. Lower speeds are required
for viscous liquids, consult the factory for proper
speeds and horsepower requirements.

4.

SELF-PRIMING – Primes at low or high speeds. For
vertical dry suction lift of 10 feet, a minimum of 860
RPM is required. Pump will produce suction lift up to
22 feet when wet. 

Explosion hazard.  Motor can spark.  Explosion 
& death can occur.  Do not use where flammable
vapors are present.

WARNING

!

WARNING

!

Explosion hazard.  Do not pump 
gasoline, solvents, thinners or other 
flammable liquids.  To do so can cause 
an explosion resulting in injury or death.

PumpAgents.com - buy pumps and parts online

PumpAgents.com - Click here for Pricing/Ordering

Отзывы: