FEATURES
Pump Type: 30570-2XXX Pump Head
30570-3XXX Pump Head
30570-4XXX Close Coupled
30570-5XXX Close Coupled
Body:
316 Stainless Steel
Impeller:
Neoprene or EPDM
Shaft Seal:
Mechanical; Carbon-on-Ceramic or
Tungsten Carbide; Nitrile
Ports:
1-1/2" ACME Threads with Bevel Seat or
Clamp Type
Shaft:
316 Stainless Steel
Motor:
230/460 Vac, 3 Phase, 60Hz, 5 HP
1750 RPM, TEFC, C-Face, 184 TC Frame
Weight:
30570-2XXX 30.0 lb (18.6 kg) Approx.
30570-3XXX 30.0 lb (18.6 kg) Approx.
30570-4XXX 93.5 lb (42.5 kg) Approx.
30570-5XXX 93.5 lb (42. kg) Approx.
VARIATIONS AVAILABLE
Model
Description
30570-2005
Standard Pressure, Neoprene Impeller,
30570-4005
Carbon Seal, ACME Ports
30570-2105
Standard Pressure, Neoprene Impeller,
30570-4105
Tungsten Carbide Seal, ACME Ports
30570-3005
Standard Pressure, Neoprene Impeller,
30570-5005
Carbon Seal, Clamp Ports
30570-3105
Standard Pressure, Neoprene Impeller,
30570-5105
Tungsten Carbide Seal, Clamp Ports
APPLICATIONS
DAIRY: Transfer and processing of raw milk, cream, milk
whey, buttermilk, condensed milk.
FOODS: Processing of eggs, sugar liquors, brines, catsup,
chocolate, glaze, gelatin, honey, jams, jellies, mayonnaise,
molasses, mustard, pickle relish, vinegar, water, yeast
slurries, syrups, liquids containing solids in suspension
such as chopped tomatoes, nuts, peanut butter.
BEVERAGE: Circulating and transferring alcohols, beers,
brewery slop, cider, distillery wort, extracts, flavors, juice,
mash, soft drink syrups, wines.
PHARMACEUTICAL: Moving medicines, cosmetics,
process chemicals, lotions, preparations, filtering
solutions, used as a filling line supply pump.
OPERATING INSTRUCTIONS
1.
INSTALLATION – Pump may be mounted in any
position. The rotation of the pump shaft determines
the location of the pump's intake and discharge ports.
(Refer to dimensional drawing.) Pump is normally
assembled at factory for clockwise rotation looking at
end cover. If counterclockwise rotation is desired,
follow steps 1 and 2 of disassembly and step 9 of
assembly instructions to change direction of impeller
blade deflection under cam.
2.
MOTOR SELECTION – Pump Head is designed to fit
a 184 TC Frame NEMA C-Face Motor. Motor should
be rated 5 horsepower at 1750 RPM with a service
factor of one. Due to high bearing loads, motor should
be ball bearing equipped with the front bearing locked
against axial movement. Motor should be capacitor
start and foot mounted.
3.
SPEEDS – 100 RPM to the maximum shown in the
performance curves. For longer pump life, operate at
lowest possible speeds. Lower speeds are required
for viscous liquids, consult the factory for proper
speeds and horsepower requirements.
4.
SELF-PRIMING – Primes at low or high speeds. For
vertical dry suction lift of 10 feet, a minimum of 860
RPM is required. Pump will produce suction lift up to
22 feet when wet.
Explosion hazard. Motor can spark. Explosion
& death can occur. Do not use where flammable
vapors are present.
WARNING
!
WARNING
!
Explosion hazard. Do not pump
gasoline, solvents, thinners or other
flammable liquids. To do so can cause
an explosion resulting in injury or death.