FEATURES

Pump Body:

Polypropylene

Diaphragm:

*

Geolast

®

, oil resistant

Valves:

**

Viton

®

, oil resistant

Motor:

12V/24V DC with integral power
switch

Receiver:

Plastic with 3.5 Gal. (13.2L)
(maximum) capacity tank

Battery Leads:

7 ft. (2.1m) with alligator clips

Suction Tube:

8 ft. (2.4m), oil & heat resistant

Dimensions:

Weight:

3.5 lb (1.6 kg)

OPERATING INSTRUCTIONS

1.

Run the engine for approximately 5 minutes to heat oil
to approximately 160°F (71°C), then shut off
engine prior to oil removal.

2.

Insert 1/4" (6 mm) tube into pump inlet port and be
sure that it is securely in place.

3.

Open the vent cap located on hose retainer strap,
vent cap must be opened to allow tank to vent air.

4.

With the pump switch in the off position (to avoid
sparks), clamp the power-leads’ alligator clips to a
12V DC battery (red to positive; black to negative).

5.

With the engine off, remove the dipstick, and insert
the 1/4" (6 mm) oil change probe through the dip-
stick tube until it contacts the bottom of the oil pan. It
may help to measure the probe against the dipstick,
add an inch and mark the probe. Do not push the
probe too far into the dipstick tube or it may curl up
and out of the oil. It may be useful to tape the probe
in place during evacuation.

6.

To evacuate the oil, switch on the pump using the
rocker switch at the rear of the motor. Watch for flow
in the probe. If no flow appears in 15 seconds, check
the probe for sediment blockage. Clean the probe
and reset it 1/4" (6 mm) off the pan bottom.

7.

The pump will speed up when the oil has been removed.
An average 5 Quart (5 liters) oil capacity engine will take
around 10 minutes to drain.

8.

Switch off pump before removing alligator clips from
the battery, to avoid sparks.

9.

Remove probe from dipstick tube while wiping with a
rag to prevent oil drips.

10. To empty the container, unscrew the pour cap and

pour

the

oil

into

a

suitable

container

for

disposal/recycling.

11. For extended storage, flush pump with water based

degreaser solution.

NOTICE: Always recycle used oil in compliance with
federal and local legislation. Handle petroleum products
in an environmentally responsible manner.

*Geolast is a registered trademark of Monsanto.

**Viton is a registered trademark of du Pont de Nemours & Co.

Model

Amp

Fuse

Number

Voltage

Draw

Size

17860-0012

12

4

5

17860-0024

24

3

5

Explosion hazard. Motor switch must be in
"OFF" position when connecting and 
disconnecting alligator clips to battery terminal 
and ground. The switch in an "ON" position can 
cause an electrical spark which can result in 
explosion. Injury or death can occur.

WARNING

!

Explosion hazard.

Take necessary precautions 

  to   ventilate   area   around   battery of   potentially

explosive gases

.

Continue   ventilation   during 

  oil   changing   procedure.     Failure  to  do  so  can 
  result   in   explosion.

Injury   or   death  can  occur.

WARNING

!