background image

Model 17800-Series

PORTA QUICK OIL CHANGER

FEATURES

Pump Body:

Bronze construction

Impeller:

Nitrile (oil resistant)

Shaft Seal:

Lip Type

Motor:

Reversible with integral reversing
switch

Container:

Plastic with 14 quart capacity

Power Cord:

8 feet with alligator clips

Suction Hose:

4 feet of neoprene hose with
40 inch Teflon* dipstick probe

Dimensions:

13-1/2" (343mm) diameter,

13-5/8" (354mm) high

Weight:

9 lb (4.1 kg)

OPERATING INSTRUCTIONS

1.

Run the engine approximately 5 minutes to heat oil
(minimum oil temperature 140°F; maximum 185°F),
then shut off engine prior to oil removal.

2.  Push the 1/2" suction hose onto the pump inlet hose

fitting. Position one hose clamp on the end and 
tighten to secure the hose to the hose barb.

3.

If using the 1/4" dipstick probe (instead of the
Female Garden Hose Connector), insert the probe
into the 1/4" x 1/2" (approximately 1" long) rubber
bushing until the end of the probe and the bushing
are flush with each other. Slide the hose clamp over
the end of the 1/2" hose and position the end of the
plastic probe, with bushing attached, in the end of
the suction hose. Slide the hose clamp to a position
where it will be approximately centered over the
probe/ hose bushing, and with a pair of pliers,
squeeze it together very tightly to affect a positive
airtight seal.

If using the Female Garden Hose Fitting, install it
onto the end of the 1/2" suction hose by inserting the

1/2" barb fitting into the
hose and secure it by
screwing  together  the
two halves of the plastic
clamp on the hose at the
position of the barb.

4.

Clamp the power cord
alligator  clips  (red  to
positive  and  black  to
negative) to the termi-
nals of an appropriate
voltage battery.

NOTICE: Failure to use proper size fuse in power cord
fuse  holder  may  cause  motor  damage  and  void 
w a r r a n t y.

Model

Amp

Fuse

Number

Voltage

Draw

Size

17800-2000

12

7

10

17800-2090**

12

7

10

17800-2024**

24

3-1/2

5

** Models  17800-2090  and  17800-2024  conform  with

EN50081-2 for suppression of electro-magnetic interference
and are

marked.

Содержание 17800 series

Страница 1: ... and the bushing are flush with each other Slide the hose clamp over the end of the 1 2 hose and position the end of the plastic probe with bushing attached in the end of the suction hose Slide the hose clamp to a position where it will be approximately centered over the probe hose bushing and with a pair of pliers squeeze it together very tightly to affect a positive airtight seal If using the Fe...

Страница 2: ...n of required flow If using the 1 4 probe watch for oil flowing through it If oil does not appear in about 10 seconds check the probe for possible sediment blockage and remove if present NOTICE If the motor does not turn when first switched on switch off the pump and loosen each of the end cover screws a couple of turns Switch the pump on until the motor turns and then switch it off again Retighte...

Страница 3: ...4 Tap body lightly between ports and remove body from motor 5 With a 1 2 diameter dowel push against the shaft seal from back motor side of the body to dislodge it from the seal bore NOTE Do not tamper with or disassemble motor ASSEMBLY 1 Lubricate seal with water and position it in seal bore with lip or hollowed out side of seal pointing towards the impeller bore With a 1 2 diameter dowel push ag...

Страница 4: ...998 Or to such alternate locations as may be designated on the product its container or this sheet Repair or replacement made under this warranty will be shipped prepaid to Buyer C EXCLUSIONS FROM WARRANTY AND LIMITATION OF LIABILITY 1 The foregoing warranty is limited solely as set forth herein and applies only for the period designated above 2 JABSCO SHALL NOT BE LIABLE FOR ANY LOSS DAMAGE SPECI...