Model 17800-Series
PORTA QUICK OIL CHANGER
FEATURES
Pump Body:
Bronze construction
Impeller:
Nitrile (oil resistant)
Shaft Seal:
Lip Type
Motor:
Reversible with integral reversing
switch
Container:
Plastic with 14 quart capacity
Power Cord:
8 feet with alligator clips
Suction Hose:
4 feet of neoprene hose with
40 inch Teflon* dipstick probe
Dimensions:
13-1/2" (343mm) diameter,
13-5/8" (354mm) high
Weight:
9 lb (4.1 kg)
OPERATING INSTRUCTIONS
1.
Run the engine approximately 5 minutes to heat oil
(minimum oil temperature 140°F; maximum 185°F),
then shut off engine prior to oil removal.
2. Push the 1/2" suction hose onto the pump inlet hose
fitting. Position one hose clamp on the end and
tighten to secure the hose to the hose barb.
3.
If using the 1/4" dipstick probe (instead of the
Female Garden Hose Connector), insert the probe
into the 1/4" x 1/2" (approximately 1" long) rubber
bushing until the end of the probe and the bushing
are flush with each other. Slide the hose clamp over
the end of the 1/2" hose and position the end of the
plastic probe, with bushing attached, in the end of
the suction hose. Slide the hose clamp to a position
where it will be approximately centered over the
probe/ hose bushing, and with a pair of pliers,
squeeze it together very tightly to affect a positive
airtight seal.
If using the Female Garden Hose Fitting, install it
onto the end of the 1/2" suction hose by inserting the
1/2" barb fitting into the
hose and secure it by
screwing together the
two halves of the plastic
clamp on the hose at the
position of the barb.
4.
Clamp the power cord
alligator clips (red to
positive and black to
negative) to the termi-
nals of an appropriate
voltage battery.
NOTICE: Failure to use proper size fuse in power cord
fuse holder may cause motor damage and void
w a r r a n t y.
Model
Amp
Fuse
Number
Voltage
Draw
Size
17800-2000
12
7
10
17800-2090**
12
7
10
17800-2024**
24
3-1/2
5
** Models 17800-2090 and 17800-2024 conform with
EN50081-2 for suppression of electro-magnetic interference
and are