4.2 User codes setting 

 

There can be up to 14 different user codes for individual users. The system stores 

to its memory which code was used for what event and when. This data can go to a 

Central monitoring station as well  and can also be viewed by a PC with Comlink 

software.  

All user codes are empty as a factory default and the supervisor should program 

them entering:  

  

     

F   6     xxxx   yy    zzzz  

 

where 

xxxx

 is the master code,  

yy

 is the user code index (from 01 to 14) and 

zzzz

 is the new user code.  

 

Example: 

If the master code is 1234 and the user 3 new code should be 5277 enter: 

 

F  6   1234  03  5277

 

 

To delete a particular user code, 

enter 0000 as the new code (combination 

0000 can not be used as a valid code).

 

 

Example: 

If the master code is 1234 the user 3 code can be deleted by: 

 

F  6   1234  03  0000

 

 

Notes: 

  You can program new codes only when the system is disarmed. 

  The supervisor should record the codes to the table on last page of this 

manual (it should be kept hidden in a safe place). 

   

  If the system is split, the supervisor can change the user codes, but can 

not change to which section the particular code belongs (only the installer 

can change this).  

 

4.3 Internal clock setting 

 

 

The control panel has a built in real time clock. All events are stored to the event 

memory including the time & date. The clock should be set after installation, but 

the supervisor can set the clock while in the user mode.  

To switch the control panel to the user mode enter 

F 0 master code

. User 

mode will be indicated by a 

U

 on the keypad. To set the clock enter: 

 

4   hh mm DD MM YY  

 

where: 

hh

 = hours; 

mm

 = minutes; 

DD

 = day; 

MM

 = month and  

YY

 = year 

 

Example: at 21:30 on March 19. 2005 enter:    

4   21 30 19 03 04

 

 

To 

exit user mode

 press 

N

Alarm system JA-63 „Profi“ 

- 9 - 

MGK51504 

Содержание Profi

Страница 1: ...JA 63 Profi User manual...

Страница 2: ...equent period of two 2 years Should your Product need warranty service please return it to the dealer from whom it was purchased Conditions 1 The warranty is valid only if the original receipt issued...

Страница 3: ...on information received from a wireless item or wireless communication of the keypad in progress Armed continues armed slow blinking exit delay fast blinking entrance delay Power continues AC power ba...

Страница 4: ...rmed B section is armed split system complete arming system is completely armed bypass warning that some detectors are bypassed indicated while arming key pressed waiting for more data to complete the...

Страница 5: ...ill beep once and the exit delay countdown will start ARMED indicator will flash during exit delay you should leave the protected area within the duration of the exit delay If there are 4 beeps while...

Страница 6: ...telephone line depends on installation settings Panic alarm can be triggered On the keypad press the panic key and then enter your access code On the remote control RC 4x press the and buttons simulta...

Страница 7: ...also be viewed on the keypad by entering F 4 will show the last recorded alarm or failure Press key 4 multiple times to go deeper in to the memory 3 8 Split system arming The system can be split by th...

Страница 8: ...ypad or by SMS messages the control panel must be equipped with GSM communicator for this feature Installer can program that this feature will work only when the entry is followed by a user code 4 Use...

Страница 9: ...eleted by F 6 1234 03 0000 Notes You can program new codes only when the system is disarmed The supervisor should record the codes to the table on last page of this manual it should be kept hidden in...

Страница 10: ...tomatic arming and disarming can be overridden manually anytime by a user code or a remote control If the control panel is in the requested arming mode before the action time the programmed action wil...

Страница 11: ...ith a JA 60GSM communicator please look at the JA 60GSM user manual for details about user s setting 5 2 JA 65X Telephone communicator If the control panel is equipped with a JA 65X telephone communic...

Страница 12: ...r mode Enter F0 master code to switch to the user mode U will be indicated on the keypad No alarm can be triggered while in the user mode and any triggering of a detector a remote control or a panic b...

Страница 13: ...e battery life Recommendations the system should be annually inspected by a professional installer The control panel and the outdoor siren back up batteries should be replaced with new ones after 5 ye...

Страница 14: ...0 Master code supervisor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 c1 c2 c3 c4 c5 c6 c7 c8 Telephone communicator setting memory calling to tel number notes 1 2 3 4 5 Pager Timers exit delay sec entrance delay...

Страница 15: ...in the house detectors type reaction section A B S WIRELESS DETECTORS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 WIRED INPUTS 1 2 3 4 I instant D delayed F fire P panic T tamper N next delayed Alarm syst...

Страница 16: ...Notes Alarm system JA 63 Profi 16 MGK51504...

Отзывы: