background image

PG-4G 

1/2 

MEG52202 

PG - 4 Guard 

 

PG-4G is a 12-channel transceiver of panic signals transmitted from or 

to other PG-4G units. The panic transmission can be triggered by the 

remote controls (RC-11, RC-22, RC-28). 

If the unit is triggered by the remote control it will send the signal to 

other units that have been enrolled to the one, which is transmitting the 

panic signal. The received signal is indicated by the corresponding LED 

diode placed on the front panel of the unit. By the position of the active 

LED diode is to be found from which unit (place) the signal was sent. 

Activation can be also indicated by the built-in buzzer (depending on a 

jumper BUZZER) or by an external siren, flashing light, telephone dialer 

etc. 

It also cooperates with a pocket receiver PG-4R. Every panic signal is 

sent to all enrolled PG-4G units as well as to the receivers PG-4R. 

 

 

Specification        

 

Power supply:                             

 

12 V DC 

Stand-by consumption:        

 

55-100mA 

Maximal supply current: 

 

0,5 A  

Max output load: 

 

12 V, max. 250mA 

Output OUT for TD-101connection   

 12 V, max. 5mA 

Dimensions:                                  188 x 135 x 40 mm (without antenna) 

Working environment:      

              

   indoor use (class II) 

Working temperature: 

 

-10 to +40

o

 

Built-in receiver of the remote controls 

Compatible remote controls: 

 

RC-11, RC-22, RC-28 

Number of controllers: 

up to 30 

Coding:               digital, each remote control has a unique floating code 

Working distance: 

  depending on the remote control - 

 

 

Max 100m open area 

Operating frequency: 

433.9 MHz, ISM EN 300220 

 

Built-in receiver/transmitter for communication with other units 

PG-4G 

Number of cooperating units:                                                     up to 13 

Coding: 

                                              digital 

Working distance: 

 

up to 2 km (open area) 

Operating frequency: 

448.17 MHz 

Transmitting time 

3 sec. 

Radiated power 

0.5 W 

External antenna (optional) 

Yes, type AN-01A, AN-02, AN-03 

 

Wireless local indication of the activation (optional) 

Compatible receivers: 

 

PG-4R, PG-4M 

Number of receivers: 

 

unlimited 

Working distance: 

 

up to 2 km (open area) 

In Norway and Belgium can be operated according to ERC REC 70-03 

as e SRD. 

 

Hereby, Jablotron Ltd. declares that this PG-4G is in compliance with 

the essential requirements and other relevant provisions of Directive 

1999/5/EC.  
Original of the conformity assessment can be found at the web page 

www.jablotron.cz

, section Technical support. 

Note:

 Although this product does not contain any harmful materials we 

suggest you to return the product to the dealer or directly to the 

producer after usage. 

 

Installation 

 

The metal case should be installed on a wall with its antenna in a 

vertical position. The unit should not be installed close to any metal 

structures or other objects obstructing radio signal transmission.  

Route the wires through the hole in the rear part of the housing. Attach 

the case to the desired place using the provided screws. 

 

 

Terminal description: 

+12V, GND

  

DC power input 12 V DC  

OUT 

Output  for a telephone dialer (TD-101) activation, 

 

connected to ground in case of the alarm, max. load 5mA)

 

SIR 

output for external indication 12V / 250mA

 

max, timeout 

 

60 minutes

 

+U, GND

  

DC power output 12 V DC 100mA max 

  

Indicators and controllers for installation/service 

 

The indicators 1-12 on the cover indicate the status of the unit during 
the learning mode. Buttons 

  and 

  (up or down)  are used to 

control the learning mode (see figure 1).   

 

 

figure 1 

Other controlling buttons/jumpers are placed on the main board (see 

figure 2): 

TRANSMITER

RECEIVER

BUZZER

JP4

ANT

JP1

LEARN

TRANSMIT

TEST

EXP

RS 232

+

 U

G

N

D

O

UT

SI

R

+

12

V

G

N

D

ADRESS

 

figure 2 

Button 

LEARN

   

to enroll the remote controls 

LED    

LEARN

   

indicates opening of the enrollment mode 

LED    

TEST

   

indicates  activation  of  enrolled  remote  control  in                                                                                                

 

the test mode (JP1) 

Button

 TRANSMIT

  to transmit the enrolling signal to other PG-4G 

units  

LED 

TRANSMIT  

indicates the transmission of PG-4G  

Jumper 

JP1

 

right position – if the unit is triggered by the panic 

button it will start transmitting to other PG-4G 

units as well as to the local receivers PG-4R if 

there are any 

 

left position – if the unit is triggered by the panic 

button it will start transmitting only to other PG-

4G receivers 

Jumper 

JP4

 

 

Close upper and middle pins to test the remote 

controls 

 

 

Open – normal function 

Jumper 

BUZZER

  Close – to switch ON the built-in buzzer 

 

 

Open – to switch OFF the built-in buzzer  

RS-232

 

 

connector for PC connection (RS-232) 

ANT

 

AN-01A external antenna connector (when AN-

01A is used, the rod antenna must be 

disconnected) 

EXP

 

   connector for external communication 

 

Recommended procedure of setting 

 

1.  First of all enroll the remote controls to each unit.  

2.  If any receivers PG-4R (M) are used enroll them after that.   

3.  Enroll other PG-4G units. 

Отзывы:

Похожие инструкции для PG-4 Guard