PG-4G
1/2
MEG52202
PG - 4 Guard
PG-4G is a 12-channel transceiver of panic signals transmitted from or
to other PG-4G units. The panic transmission can be triggered by the
remote controls (RC-11, RC-22, RC-28).
If the unit is triggered by the remote control it will send the signal to
other units that have been enrolled to the one, which is transmitting the
panic signal. The received signal is indicated by the corresponding LED
diode placed on the front panel of the unit. By the position of the active
LED diode is to be found from which unit (place) the signal was sent.
Activation can be also indicated by the built-in buzzer (depending on a
jumper BUZZER) or by an external siren, flashing light, telephone dialer
etc.
It also cooperates with a pocket receiver PG-4R. Every panic signal is
sent to all enrolled PG-4G units as well as to the receivers PG-4R.
Specification
Power supply:
12 V DC
Stand-by consumption:
55-100mA
Maximal supply current:
0,5 A
Max output load:
12 V, max. 250mA
Output OUT for TD-101connection
12 V, max. 5mA
Dimensions: 188 x 135 x 40 mm (without antenna)
Working environment:
indoor use (class II)
Working temperature:
-10 to +40
o
C
Built-in receiver of the remote controls
Compatible remote controls:
RC-11, RC-22, RC-28
Number of controllers:
up to 30
Coding: digital, each remote control has a unique floating code
Working distance:
depending on the remote control -
Max 100m open area
Operating frequency:
433.9 MHz, ISM EN 300220
Built-in receiver/transmitter for communication with other units
PG-4G
Number of cooperating units: up to 13
Coding:
digital
Working distance:
up to 2 km (open area)
Operating frequency:
448.17 MHz
Transmitting time
3 sec.
Radiated power
0.5 W
External antenna (optional)
Yes, type AN-01A, AN-02, AN-03
Wireless local indication of the activation (optional)
Compatible receivers:
PG-4R, PG-4M
Number of receivers:
unlimited
Working distance:
up to 2 km (open area)
In Norway and Belgium can be operated according to ERC REC 70-03
as e SRD.
Hereby, Jablotron Ltd. declares that this PG-4G is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC.
Original of the conformity assessment can be found at the web page
, section Technical support.
Note:
Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the
producer after usage.
Installation
The metal case should be installed on a wall with its antenna in a
vertical position. The unit should not be installed close to any metal
structures or other objects obstructing radio signal transmission.
Route the wires through the hole in the rear part of the housing. Attach
the case to the desired place using the provided screws.
Terminal description:
+12V, GND
DC power input 12 V DC
OUT
Output for a telephone dialer (TD-101) activation,
connected to ground in case of the alarm, max. load 5mA)
SIR
output for external indication 12V / 250mA
max, timeout
60 minutes
+U, GND
DC power output 12 V DC 100mA max
Indicators and controllers for installation/service
The indicators 1-12 on the cover indicate the status of the unit during
the learning mode. Buttons
and
(up or down) are used to
control the learning mode (see figure 1).
figure 1
Other controlling buttons/jumpers are placed on the main board (see
TRANSMITER
RECEIVER
BUZZER
JP4
ANT
JP1
LEARN
TRANSMIT
TEST
EXP
RS 232
+
U
G
N
D
O
UT
SI
R
+
12
V
G
N
D
ADRESS
figure 2
Button
LEARN
to enroll the remote controls
LED
LEARN
indicates opening of the enrollment mode
LED
TEST
indicates activation of enrolled remote control in
the test mode (JP1)
Button
TRANSMIT
to transmit the enrolling signal to other PG-4G
units
LED
TRANSMIT
indicates the transmission of PG-4G
Jumper
JP1
right position – if the unit is triggered by the panic
button it will start transmitting to other PG-4G
units as well as to the local receivers PG-4R if
there are any
left position – if the unit is triggered by the panic
button it will start transmitting only to other PG-
4G receivers
Jumper
JP4
Close upper and middle pins to test the remote
controls
Open – normal function
Jumper
BUZZER
Close – to switch ON the built-in buzzer
Open – to switch OFF the built-in buzzer
RS-232
connector for PC connection (RS-232)
ANT
AN-01A external antenna connector (when AN-
01A is used, the rod antenna must be
disconnected)
EXP
connector for external communication
Recommended procedure of setting
1. First of all enroll the remote controls to each unit.
2. If any receivers PG-4R (M) are used enroll them after that.
3. Enroll other PG-4G units.