Страница 2: ...ble alarms 9 6 20 Wireless siren alarm enabled IW and EW 9 6 21 Bypass user approval 9 6 22 Final door detectors 9 6 23 Partial setting arming or system splitting 9 6 24 Automatic summer time daylight saving time 10 6 25 Pulse reaction of tamper sensors 10 6 26 Operating the PG outputs using 8 and 9 10 6 27 Permanent alarm status display for a set system 10 6 28 Tamper alarm if unset 10 6 29 Recor...
Страница 3: ...y cable to the left side of the power supply terminal separately from the other cables If requested install a rear tamper sensor and attach a spring to it included in the package The control panel box can be attached to the wall using screws make marks on the wall using the holes on the box and drill holes for the anchoring screws The two top holes are used to hang the box on screws on the wall th...
Страница 4: ...iple detectors to the inputs schematically The used input zone must be terminated by a 1k resistor in stand by state When connecting a trigger contact to the zone always use a parallel 1k resistor Thus it is possible to connect up to 5 trigger contacts in series Tamper contacts should be connected in series without resistors They therefore interrupt the whole loop You can use an unlimited amount o...
Страница 5: ...ery connection It is possible to use a 12V gel cell backup battery with a capacity of up to 18Ah in the control panel The EN 50131 1 standard requires a 12 hour minimum backup time in case of a power grid failure For the standby consumption of all system devices see fig 8 Always fix the backup battery in the box using the supplied Velcro fastener tape thus avoiding possible injury caused by the ba...
Страница 6: ...e You can carry the wireless keyboard with you during the inspection Notes JA 80P and JA 85P motion detectors can be tested max 15 minutes after closing their cover After that the detectors ignore frequent movements see the detector manual Devices can also be tested in Service mode see 7 4 5 3 Signal strength measuring 1 The control panel must have its antenna connected and it must be in Service m...
Страница 7: ...e also wirelessly transmitted for UC and AC modules The status of PGX and PGY outputs can be displayed by pressing the key The names of the outputs can be edited see 6 47 Example for unsplit systems Assigning an ON OFF function to the PGX output sequence 237 Assigning a panic function to the PGY output sequence 244 Factory default setting PgX ON OFF PgY anything set 6 5 Changing telephone numbers ...
Страница 8: ... any intruder detector gets triggered i e a detector with an instant delayed or next delayed reaction an alarm will not be caused but the control panel will record a so called unconfirmed alarm If any other intruder detector is triggered in a set section within 40 minutes of the above event an intruder alarm will be triggered If no other detector is triggered during this period the control panel w...
Страница 9: ...70 seconds will begin and be indicated If a final door detector is triggered during the exit delay the exit delay will be extended by the time in which the detector is still triggered So if for example the door is left continuously open the exit delay will never end If a final door detector is de triggered the system will wait five more seconds during which beeping gets faster and if the door is n...
Страница 10: ...ay enabled 6 8 3 0 display time a maximum of 3 minutes if any section is set armed Notes European legislation requires status displaying to be suppressed within three minutes of setting arming the system no matter how much or little of the system is set This feature can be used to ignore this requirement if appropriate The wireless keypad can continuously display the status if powered by an extern...
Страница 11: ...e in the premises 6 9 4 0 standard control panel sensitivity 6 9 4 1 higher control panel sensitivity Note The sensitivity of the control panel receiver should only be increased if there is no RF interference as the radio range would only be reduced if interference was present Factory default setting standard control panel sensitivity 6 37 Access by code plus card This feature increases security a...
Страница 12: ...ave a natural reaction r 1 and are assigned to section C s 3 6 41 Code card reactions and section assignment The following sequence programs the features of access codes or cards 6 2 nn r s where nn is the user position from 01 to 50 r is the reaction index from 0 to 9 see fig sis the section 1 A 2 B 3 C only has an effect in a split system except for the PG output control reaction see 6 26 Guidan...
Страница 13: ...uding wireless ones must be connected to the digital bus to save the changes to the keypad units by clicking on the OK button in the software It is recommended to connect JA 81F wireless keypads to the bus in order to save the text into them as well Factory default setting in addresses 01 to 50 there is the text Device Other default text Control panel Keypad Communicator Master code users 01 to 50...
Страница 14: ...s enabled then Setting and unsetting the alarm system is only possible using a JA 81F or JA 81E indoor keypad or a keyfob Entering a valid access code or presenting a valid card to the outdoor keypad or card reader will always open the electric door lock If the system is set and the door is opened via the outdoor keypad or reader an entrance delay will begin During this delay the system has to be ...
Страница 15: ...e system to the customer and offer him this service For more details see the relevant EN standards For further information see EN 50131 1 and other standards 10 Trouble shooting Problem Possible causes Solutions The control panel is not in service mode after being powered up The control panel does not have factory default settings Reset the control panel It is impossible to enroll a wireless devic...
Страница 16: ...onmental class II indoor general 10 to 40 C compliant with EN 50131 1 EMC EN 50130 4 EN 55022 Safety EN 60950 1 JA 82R radio module Communications frequency JA 82R 868 MHz ISM band Can be operated according to ERC REC 7003 Radio emissions ETSI EN 300220 these signals are also transmitted wirelessly to wireless sirens and AC and UC receiver modules Jablotron Alarms a s hereby declares that the JA 8...
Страница 17: ...r PGX and 90 91 for PGY 8 Single 2 s pulse keys 8 X 9 Y Enablement of telephone number changes in maintenance mode 25x 251 YES 250 NO NO see communicator Radio interference indication 26x 261 YES 260 NO NO YES 30 s or longer Radio communication supervision 27x 271 YES 270 NO NO YES RESET enabled 28x 281 YES 280 NO YES Master control panel enrollment to a sub control panel for setting arming contro...
Страница 18: ...he number of triggered tamper sensors 6810 react with a tamper alarm to all triggered tamper sensors X 0 Suppresses the indication of permanently triggered tamper sensors Operating the PG outputs using 8 and 9 682x 6821 YES 6820 NO YES if yes then arrow keys can also operate PGX Permanent alarm status display for a set system 683x 6831 YES 6830 NO NO suppresses the 3min display timeout Tamper alar...
Страница 19: ...3 C has to be entered even if the system is not split and setting arming has no meaning all Natural in C When the detector is disabled r 0 the tamper sensor is not triggered Natural reaction of control panel wired inputs or IN keypad input is delayed DEL Enrollment by keying in production codes nn address 01 to 50 xxxxxxxx last 8 digits of the 60 nn xxxxxx xx production code below the bar code on ...
Страница 20: ...RFID reader C O ly programmable if the sy master code or c NC new code or card ent presented once Either a code or a card can be prog e Maste ge e Master Code s reaction is s affect the Mas To make han he master code ard to the User 50 ally unset erased med to it by using the sequence d 6 MC nn NC Only programmable if the system is tot MC Master Code or card 01 to 50 nn user code or card position ...