jablotron JA-87P Скачать руководство пользователя страница 1

The JA-87P dual zone outdoor wireless motion detector - curtain 

MKU53105 

The JA-87P dual zone outdoor wireless motion detector - curtain 

The JA-87P wireless outdoor detector is a component of OASIS system. 

It is designed to detect human body movement in an outdoor environment. 

It is the FTN-RAM-PT detector produced by Optex with a Jablotron 

transmitter. The optical part of the detector has curtain characteristics of its 

lenses with a 5° angular width detection zone which makes it very suitable 

for guarding narrow spaces such as balconies, French doors, terraces, etc. 

The detector is equipped with dual-beam optics with a high immunity 

against false alarms and the detection of small animals. The detector also 

has an anti-masking function – i.e. protection against shielding its view. It is 

also equipped with two tamper contacts both of them immediately 

reporting tampering of the detector or removal from the installation place. 

The detector should be installed by a trained technician with a valid certificate 

issued by an authorised distributor. 

Detector position and installation 

The following instructions should be followed when selecting the place 

for detector installation: 
1.  The detector should be attached to a vertical wall 

2.  The detector should be installed 0.8 – 1.2 m above the ground 

3.  The best movement detection is provided when the detection zones 

intersect 

4.  No other moving objects (bushes, trees, high grass, etc.) should be 

situated in the field of sight of the detector. Avoid direct action by 

strong sources of light (sun reflections). 

Detector installation procedure 

 

 

Figure 1.:

 Detector housing: A – detector installation pad,  

B – detector base with the PCB, C – front cover of the detector with lenses, 

1 – mounting holes, 2 – blasting part of tamper contact, 3 – facing surface to be 

assembled by a screw, 4 – lenses, 5 – DIP switch for setting up, 

6 – locking screws for assembling, 7 – retractable fixation bracket 

 

1. 

Unscrew the locking screws (6) and separate parts A and B. 

2. 

Fix the installation pad (A) to the required place using mounting holes 

(1). Caution, if you want to use a tamper contact it is necessary to screw 

the blasting part (2) of the housing to ensure when someone tamper the 

detector it breaks off this part. 

3. 

Now take out the front cover to set up the detectors view and options by 

DIP switches (5). 

4. 

Position of the detection part is fixed by a plastic bracket (7), remove it in 

upper direction. 

5. 

When you set up the required angle of view, lock it by pushing of plastic 

bracket (7) back to default position. 

6. 

Set the required options by the DIP switches (5). 

7. 

Now enroll the detector to the system. 

Do not touch the detector sensing face 

 during the handling 

If you touch it coincidently, it is necessary to clean it up by a 

piece of cotton wool soaked in alcohol. 

Switching on and enrolling the detector into the system 

Study the control  panel (receiver unit) installation manual before 

inserting the battery. The control panel must be equipped with the  

JA-82R radio module. Use AA 3.6 V lithium batteries only. The correct 

position of the battery is indicated on the battery holder. When the 

battery has been installed, the transmitter sends a signal which enrolls it 

to the control panel. The control panel must be in enrollment mode at 

that time. Use switch no. 2 to set system reaction to detected movement 

(ON = instant or OFF = delay). Switch no. 1 should remain in the OFF 

position. 

Figure 2: 

1 – Jumper – let it connected 

2 – Function switch;  

3 – Terminals for detector to be connected; 

Vcc

 – red; 

TMP

 – blue; 

INP

 – yellow;  

GND

 – white, green, black 

4 – Indication LED 

 

 

Tabulka nastavení přepínače funkcí (2)

 

1  ON  State 

 

Pulse *) 

2  ON  Instant reaction 

Delay reaction 

 

Setting up the optical part of the detector 

A detection range of 5 m 

or 2 m can be set. The 

setting is done by turning the 

bottom detector lens (closer 

to the centre of the cover). 

The lens shape is designed so 

that its projecting part 

uncovers the detection 

distance which you have 

selected when it is inserted 

back into the plastic base (see 

the picture below). Do not turn the upper lens!

 

 

Anti-masking (shielding protection function) 

The detector is equipped with an anti-masking function –  protection 

against physical shielding. When enabled, any potential covering of the 

detector is detected by reflected IR ray pulses. Covering is indicated if 

the obstacle is nearer than 10 cm from the detector.  

After inserting the battery and closing both plastic parts the detector 

does an analysis of the space in front of itself for 1 minute – to calibrate 

itself. In this time the detector does not detect any movement at a 

distance shorter than 1 m. Then anti-masking test mode starts running 

for 10 minutes. In test mode IR pulses are transmitted every 20 s; any 

covering is detected in 20 s maximum if covering continues. When test 

mode expires, the detector goes into the usual working mode. Now IR 

pulses are transmitted every 3 minutes. Covering detection is indicated 

in 3 minutes maximum if covering continues. The reaction to covering 

the detector is a tamper alarm. Recovery occurs in 20 s. Default setting: 

disabled. 

 

Other detector properties can be set using a switch in the detector 

 

 

ON

 

OFF

 

test mode

 

normal operation  

5 sec energy saving mode  

120 sec

 

fault signal triggers N.O 

NC

 

LED enabled 

LED disabled

 

normal immunity of detection 

increased immunity of 

detection 

anti-masking enabled 

anti-masking disabled 

 

The default settings are 

in bold letters.

 

 

1. 

Test mode: indication by LED enabled; Energy saving mode 

completely disabled (DIP switches 2 and 4 are ignored, but not in 

Normal mode). 

2. 

Energy saving mode: When movement has been detected, the 

detector goes into sleep mode for 5 or 120 s 

3. 

Selection of NO/NC logic for the output relay (for Jablotron systems 

use the OFF setting) 

4. 

Enable/disable indication LED when the detector has been activated.  

5. 

Immunity against false alarms. 

6. 

ANTIMASKING-  see  the paragraph 

Anti-masking (shielding 

protection function)

 

 

Отзывы: