jablotron JA-82Y Скачать руководство пользователя страница 5

The JA-82Y GSM communicator installers manual 

5/13 

MDL51109 

 
 

 

Only characters which can be keyed in from the system keypad (0 to 9, * and 
#) can be used in the sequences   

 

When a valid instruction is received, the communicator performs the sequence 
by simulating entering the keys on the keypad. A comma in the SMS is taken 
as a pause in the sequence entering.  

 

If you want to remotely reprogram the system it must first be unset and then 
switched to programming mode  

 

The number of sequences in one SMS is limited by the maximum size of the 
SMS in the GSM network. 

Example:

 by sending SMS 

8080_PRG_

08080_201_#

 the exit delay will be set 

to 10s 

6.23. Registration code   

You need to know the communicator  registration code  when first connecting  via 
the  OLink  software  through  the  Internet.  The  code  is  stated  on  the  label  on  the 
communicator  panel  but  it  can  also  be  sent  to  the  mobile  phone  by  SMS.  To 
request a registration code, enter:  

911 xx...x

where 

xx...x

 is the number of the phone where  the code should be sent   

Notes: 

 

The time needed for delivery of the code depends on the current GSM network 
speed 

 

Each  communicator  has  a  unique  registration  code  in  the  following  format:  
xxxxx-xxxxx-xxxx 

6.24. Remote access password  

This security key for data communication is a condition for remote access to the 
system via OLink program. It is set through the following sequence: 

894 xxx …x 

where: 

xxx…x  

is a security access password which can have 1 to 32 digits 

 

Note:

 If a password using letters is required, it must be set in the OLink software or 

by an SMS message. Letters are case-sensitive. 

Factory default setting:  

1234ABCD 

6.25. Restarting GSM communication 

After 

893

 has been entered, the communicator disconnects from the GSM network 

and then re-registers itself. This re-registration does not change any settings in the 
communicator. It should be used after GSM network faults or data collisions and in 
some  networks  it  also  has  to  be  used  after  a  blocked  SIM  card  has  been 
unblocked by the GSM provider. It is also possible (if the SIM card can still receive) 
to trigger GSM network re-registration by sending the SMS instruction:  

code GSM 

6.26. Communicator reset 

Entering  998080  returns  the  communicator  to  its  factory  default  settings. 
Telephone numbers will be erased together with all untransmitted reports but the 
text settings in the communicator will not be changed. 

6.27. 

SIM card’s PIN code 

It  is  recommended  to  use  a  SIM  card  with  disabled  PIN  protection  in  the 
communicator. If you still want to use a card with PIN protection, enter the PIN by 
entering  the  following  sequence  (it  must  be  entered  after  the  control  panel  has 
been  powered up): 

920 PIN

Example:

 If the SIM card PIN code is 1234, enter 

9201234

0

 

Notes: 

 

If the communicator does not register to the GSM network within 1 minute of 
the PIN being entered (this problem is shown by the red LED flashing), then 
you either entered a wrong PIN or the GSM signal is too weak. In such a case: 

 

enter 920*0 while in control panel service mode (erases the PIN entered in the 
communicator) 

 

disconnect the control panel power (mains and battery) 

 

take out the SIM card, insert it into a mobile phone and check whether the PIN 
is correct. Check whether the signal strength at the location of the control panel 
is sufficient  

 

if you know the right PIN code and the GSM signal is strong enough, put the 
SIM card back into the communicator, turn on the control panel power and then 
enter  the  correct  PIN  code  (920  PIN  *0)  and  wait  until  the  communicator 
registers to the GSM network (its red LED should turn off within a minute)  

 

The  communicator  memorizes  the  set  PIN  and  it  will  use  it  automatically 
whenever it registers to the GSM network again. 

 

If you are replacing the SIM card in the communicator with another one and the 
former one used a PIN code, first switch the control panel to service mode and 
enter 920*0 to erase the former PIN code.  The SIM card can then be changed. 

Warning:

 The PIN code cannot be changed if the ARC settings are locked 

Factory default setting:   

The PIN code is erased 

6.28. GPRS parameter setting 

GPRS  data  communication  (wireless  Internet  via  a  GSM  network)  is  used  for 
remote  access  via  the  OLink  software  and  also  for  communication  between  the 
system and the ARC. To use GPRS data communication it must first be enabled 
(activated) in the SIM card (contact your GSM provider for details). Depending on 
the  SIM  card  used,  the  GPRS  parameters  (APN  and  possibly  the  login  and 
password  if  the  SIM  card  requires  them)  must  be  programmed  by  sending  the 
following SMS instruction to the communicator. 

code_GPRS_ x..x_y..y_z..z 

 

where:  

Code

 

valid service system code (e.g.  8080 ) 

_

 

space 

x..x

 

SIM card APN 

y..y

 

username (do not enter if not required)  

z..z

 

password (do not enter if not required)   

 

Examples:  

For a T-mobile Czechia card enter:  code GPRS internet.t-mobile.cz 

Warning: 

The  GPRS  parameters  cannot  be  changed  if  the  ARC  settings  are 

locked  

Factory default setting:   APN = internet 

7.  Communication to the ARC 

 

 

7.1. ARC phone numbers 

Events can be reported to up to 2 ARCs (which can be independent or ARC2 can 
work  as  ARC1’s  backup).  Each  ARC  can  have  its  main  and  backup  phone 
numbers (or IP addresses) programmed with: 

Main: 

01 p xx....x

Backup: 

02 p xx....x

where: 

p

 

1=ARC1, 2=ARC2  

xxx...x

 

tel. 

number

  (max.20  digits) 

or  IP  address

 

and  port

 

–  entry  format 

example.: 

01 2 

8 192 168 001 123 08080 

0

  

where:

  

8

  (auto-converts  to  #)  signifies  an  IP  address  which  must  have  12 

digits  and  must  be  followed  by  the  5  digits  of  the  port  number  (no 
separators). 

To  erase  a  tel.  number  /  IP  address

  enter 

01p

0

  or 

02p

0

.  If 

numbers / IP  addresses  are  erased  there  will  be  no  reporting  to  that 
particular ARC. 

Notes:  

 the communicator first tries to send data to the main number / address, if it 

is not successful it tries the backup number / address. 

 the ARC address can also be entered as URL (via  OLink only) 

Factory default setting:  

all tel. numbers / IP addresses erased 

7.2. Installation (alarm system) ID for ARC use 

The  installation’s  ID  number  which  is  sent  to  an  ARC  with  every  report  can  be 
programmed with:  

03 p zz..z

where: 

p

 

1=ARC1, 2=ARC2, 3=IMG 

zz..z

 

installation ID number, max. 8 characters (0 to 9 and *1=A to *6=F) 

Factory default setting:  

for all ARCs = 0000 

 

Note:

 If you want to transmit photographs, enter 3 in the p parameter  

7.3. Selecting the ARC communication protocol 

To select the required communication protocol enter: 

04 p x 

where: 

p

 

1 = ARC1, 2 = ARC2 

x

 

0..2 = ARC type 
0 = Contact ID, 1 = Jablotron IP, 2 = Jablotron SMS 

Notes:  

 

Jablotron IP is the fastest

 of the abovementioned protocols and it is the only 

one which 

allows very frequent checking of communication reliability

 with 

the ARC (e.g. every 5 minutes). 

 

Contact  ID  protocol  can  be  directed  to  ARCs  linked  by  standard    telephone 
lines (if they support Contact ID).  

 

If  your  ARC  does  not  allow  Jablotron  SMS  or  Jablotron  IP  protocols,  please 
contact a Jablotron distributor for details on how to upgrade  your ARC 

Factory default setting:  

ARC1 - Jablotron IP, ARD2 - Jablotron SMS 

Содержание JA-82Y

Страница 1: ...commend blocking the roaming feature in the SIM card to avoid unnecessarily high communication fees contact your GSM provider for details 3 User functions of the communicator The following text describes all communicator features The installer should show the end user how to operate the functions used in the particular installation 3 1 Event reporting to the user s phone The communicator reports e...

Страница 2: ...M8 To program phone numbers to the M memories enter the following sequence while in Maintenance Service mode 81 M xxx x y 0 where M is memory number 1 to 8 xxx x is a telephone number max 20 digits y is a sequence for control via unanswered calls it does not have to be entered In a split system information from all sections ABC is reported to the 1st and 8th number positions sections AC to numbers...

Страница 3: ...2 is programmed the code 2222 will be automatically inserted in an SMS with instructions sent from the first number stored in the memory Factory default setting No code 6 7 Allowing remote access for telephone numbers Remote access is allowed for numbers saved in positions 1 to 8 Programming sequence 85 M x where M memory position tel numbers 1 to 8 x parameter 1 to allow access parameter 0 to den...

Страница 4: ...ation off 907 1 synchronization on Factory default settings on 6 18 Phone receiver loudness To set the loudness of the receiver of the phone which is used to call the communicator key in 909 x where x is a number from 1 to 9 max Factory default setting 9 max 6 19 Number to be called to maintain SIM card validity If a prepaid SIM card is used and a lack of outgoing phone calls for a certain period ...

Страница 5: ...o the communicator turn on the control panel power and then enter the correct PIN code 920 PIN 0 and wait until the communicator registers to the GSM network its red LED should turn off within a minute The communicator memorizes the set PIN and it will use it automatically whenever it registers to the GSM network again If you are replacing the SIM card in the communicator with another one and the ...

Страница 6: ... 97 Low SIM card credit balance Not reported 50 SMS transmission from a line e g from JA 84P Not reported 51 ARC communication failure 1354 reported 52 ARC communication restored 3354 reported 53 tab 3 ARC event table Source Name 701 Control panel 731 Communicator 741 Keypad 001 050 Device 1 Device 50 500 Master code 599 Service code 501 550 Code 1 code 50 tab 4 Source number table The report to t...

Страница 7: ...ated by green LED 1 being permanently lit on the left under the SIM card holder see fig 1 Communicator description Transmission to the server is signalled by a flashing green LED Successful transmission is confirmed by a long green LED flash and unsuccessful transmission is reported by rapid flashes of the green LED Successful transmission from the GSM communicator to the server is confirmed by a ...

Страница 8: ...ed in position 0 by the sequence 81 0 xxx x 0 xxx x own telephone number If you change the SIM card position 0 will be automatically erased Time synchronization see section 6 17 of the control panel is performed whenever entering into service mode or maintenance mode and if there is a difference greater than 5 minutes between the correct time and control panel time synchronization is performed aut...

Страница 9: ... Incoming call Welcome to OASiS Enter your access code Valid code CODE Can t perform the operation Enter your access code OK Invalid Valid Disarmed system Press 1 to arm OK System Armed Armed system Press 2 to disarm OK System disarmed Service mode If the system is in the requested state terminate the call The 9 key pressed Keypad simulation ...

Страница 10: ...witching to service maintenance mode 7 other event 66 Exiting service maintenance mode 7 other event 67 End of alarm indication 7 other event 78 Alarm cancelled by user S S S S S S S 7 other event 79 Control panel reset 7 other event 80 All tampers on standby 7 other event 81 All faults removed 7 other event 82 System power supply OK 7 other event 83 The communicator has no connection 5 fault 84 C...

Страница 11: ... 702 Finish setting 406 Service mode 529 Internal communication error 703 Signal strength 407 Maintenance mode 530 Internal communication restored 704 Control 409 Battery discharged 531 Communication test 705 Bypass 410 Tamper alarm 532 Unconfirmed alarm 706 Test OK 411 Alarm memory 533 Blocking after an alarm 707 Test error 412 Fault 534 Unblocking after an alarm 708 0 4 413 Power supply fault 53...

Страница 12: ...abled Enabling remote access 802 x x 0 no x 1 yes by phone and Internet x 2 yes but only by enrolled phones 1 yes Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first programmed number in memories M1 to M8 yes Autoconfiguration of GPRS 903 x X 0 autoconfiguration disabled x 1 autoconfiguration enabled Autoconfiguratio...

Страница 13: ...vent code see 7 4 x 1 report x 0 no report All events are reported see tab 3 Periodic or fixed ARC connection check 06 p x p 1 ARC1 p 2 ARC2 x 0 with a period from the last report according to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours minutes see setting...

Отзывы: