The JK-84 “Oasis” wireless alarm kit
1 / 2
MKE59901
The JK-84 “Oasis” wireless alarm kit
Installation of the JK-84 kit shall only be undertaken by technicians
holding a certificate issued by an authorized distributor. This simplified
installation manual only describes the basics, for more details see the
manuals of particular devices.
1.
Factory-default pre-enrolled devices
Address
Device
Note
03
JA-81M door
detector
Delayed reaction
04
JA-80P PIR detector
Delayed reaction
48 RC-86
keyfob
Buttons
and
pre-enrolled
49
JA-80F keypad unit
Connect a magnetic door sensor
to its IN input.
50
JA-80L indoor siren
With an RC-89 wireless door-bell
button pre-enrolled.
JA-82KR
Pre-enrolled to the JA-80L
2.
Control panel and keypad installation
1.
Attach the Control Panel (CP)
to the desired location.
2. Connect
back-up battery to the CP
(attach it securely with
adhesive tape).
3.
Connect the mains
to the CP – its green LED will start flashing
4.
Connect up the batteries in the JA-80F keypad
–
service mode
should be displayed
(if not, disconnect the keypad batteries, check
that the control panel is powered up and reconnect the keypad
batteries).
o
Keeping the
∗
key pressed while connecting the keypad batteries
will open the keypad’s internal menu which allows you to
select
the desired language
(English = 1), to exit this menu press the #
key.
o
If you exit Service mode accidentally, it can be re-entered by
keying in
∗
0 8080.
o
Close the keypad’s flip cover to save the battery while in the
service mode.
Before attaching the JA-80F keypad,
test that it functions correctly at
the desired location. We recommended
wiring up a magnetic door
sensor
(provided with the kit) to the keypad’s IN input. This will ensure
that the keypad is “woken up” whenever the door is opened (to indicate
system status, to make entrance delay beeps and to have the access
card reader ready for reading cards).
3.
Installing the detectors and the siren
1. Install the JA-81M magnetic detector, select its reaction via the
internal DIP switch (INS/DEL), connect its battery up and close the
cover.
2. Install the JA-80P PIR motion detector about 2 to 2.5 meters above
the floor, select its reaction via the relevant internal DIP switch
(INS/DEL), connect its battery up and close the cover.
3. Plug the JA-80L siren into a mains power socket.
IN
2
IN
1
GND
TM
P
1k
mag.senzor
ON/OFF
Reaction
tamper
switch
external
senzor
Main board
Transformer
Back-up battery
Mains terminal
Digital bus connector
Tamper switch
LED
Antenna connection
01
02
CO
M
03
04
EW
IW
PG
X
PG
Y
GN
D
A
B
+U
RESET
1 2 3 4
ON
OFF
Radio module
Antenna