jablotron JA-15P Скачать руководство пользователя страница 1

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

JA-15P Wireless PIR motion detector 

JA-15P Wireless PIR motion detector 

1 / 2 

MMB55101 

The JA-15P is a component of the

 

JA-10

 

system. It detects of human 

movement in building interiors. Its detection characteristics can be 

modified by using an alternative lens. False alarm immunity is available 

in two levels. The detector has a pulse reaction (only reports its 

triggering), uses wireless communication and is powered with two 

alkaline batteries. 

 

Installation 

The detector can be installed onto a wall or in the corner of the room. 

There should be no objects which quickly change temperature (electric 

heaters, gas appliances, etc.) or which move (e.g. curtains hanging 

above a radiator) or pets in the detector’s field of sight. It is not 

recommended to install the detector opposite windows or floodlights or 

in places with over-intense air circulation (close to ventilators, heat 

sources, air conditioning outlets, non-airtight doors, etc.). There should 

be no obstacles in front of the detector which might obstruct its view.  

I.

II.

 

1

2

4

5

3

 

Figure: 1 – holes for installing on a flat wall; 2, 4 – holes for installing  

at an angle (in a corner); 3 – PCB tab; 5 – cover tab 

1. 

Open the detector cover

 (by pushing the tab 5). Avoid touching  

the PIR sensor inside (11) – you could damage it.  

2. 

Take out the PCB

 – it is held by a tab (3). 

3. 

Punch through the holes 

for the screws in the plastic base and 

attach it on the wall. The recommended detector installation height 

is 2.5 m above the floor. 

4.  Set the 

Immunity

 jumper as required – see the detector settings. 

5. 

Insert the PCB back 

and proceed further according to the control 

panel installation manual. Basic procedure:

 

a.  There must be a JA-111R radio module installed in the control 

panel. 

b.  Go to the 

N-Link

  program, select the required position  

in the 

Devices

  window and launch the enrollment mode by 

clicking on the 

Enroll

 option.

 

c. 

Insert the batteries (mind the correct polarity). When the 

second battery has been inserted into the detector, 

 

an enrollment signal is transmitted to the control panel and the 

detector is enrolled to the selected position. This is followed by 

up to three minute detector stabilization phase indicated with 

LED indicator flashing.

 

6.  Close the detector cover and test its functioning.  

1400- 00- 0000- 0001

7

6

10

8

11

9

 

Figure: 6 – red detector activation indicator; 7 – battery; 8 – immunity setting 

jumper; 9 – production code; 10 – tamper contact; 11 – PIR sensor; 

Note: 

 

 

If you want to enrol a detector in which batteries have already been 

inserted, you must remove them first, then press and release the 

tamper contact in the cover (10) in order to release the remaining 

charge and then you can proceed with the enrolment. 

 

The detector can also be enrolled into the system by entering its 

production code (9) in the N-Link  program (or using a bar code 

scanner).

 

Detector settings 

Immunity level

  can be set with a jumper on a PCB inside the 

detector and it determines false alarm immunity. The 

NORM

 

level 

(default setting)

 combines basic immunity with a rapid reaction. The 

HIGH

  level provides increased immunity but the detector reaction is 

slower. 

Detector function modes 

The detector can work in two modes: 

Smartwatch

  is a default setting intended for the permanent 

monitoring of movement in the guarded area. If permanent movement 

is detected, three reports are sent every 20 s. The next report is then 

sent after 2 minutes. If the detector does not detect any movement for 

10 minutes, the mode with three reports every 20 s is used again. 

The other available detector mode is 

one-minute  interval

. When  

the detector detects movement, it sends a report and goes into standby 

mode for 1 minute. When the time is over, the detector wakes-up and 

remains active until the next detection of movement. 

To change the mode, press and hold the tamper contact in the cover, 

insert the battery and release the tamper contact 3-5  seconds after  

the battery insertion. The detector then flashes either once (smartwatch) 

or twice (one-minute  interval) to indicate the currently selected mode.  

Smartwatch is activated by default. 

Detector testing 

When you close the detector cover, its LED indicates all movement 

for a period of 15 minutes and reports it to the control panel. After this 

time the detector switches to the mode which was selected during the 

battery insertion. Detector function can also be checked via the 

Diagnostics

 

window in the

 N-Link 

program

Battery replacement 

The system sends a report automatically when the battery is low. 

Batteries should be replaced within one week. Remember to switch the 

system to Service mode before changing the batteries (otherwise a 

tamper alarm will be triggered). 

Detection characteristics  

The standard lens that 

 

is supplied with the JA-15P detector 

covers an area of 110 degrees / 12 

m. The area is covered by 3 beams 

– see the following figure.  

 

 
 

This detection characteristic is valid for standard PIR immunity. 

 

The characteristic can be changed by using an alternative lens: 

JS-7904 

Coridor lens

 Designed for long corridors – with  

a working range of up to 20 m 

Increased analysis cannot be used with such a lens! 

  

JS-7910 

Pet lens 

Equipped only with the upper beam covering 

120 degrees/12 m and not covering the floor  

(can eliminate the movement of small pets on the floor) 

JS-7902 

Vertical curtain lens

 It does not cover an area but 

creates a detection wall (can be used to create a barrier 

and report its breach) 

Note

: when a lens is replaced with a different type, test whether the 

detector covers the area correctly (a wrongly installed lens can cause 

detection errors).

 

Отзывы: