background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

The JA-159P wireless outdoor PIR detector 

 

The JA-159P wireless outdoor PIR detector 

1 / 2 

MMY51805 

 

The JA-159P wireless outdoor intruder detector is designed 

 

to detect human body movement in an outdoor environment. 
It is the VXI-RAM detector produced by Optex with a Jablotron 
transmitter. The optical part of the detector has 2 PIR sensors (dual zone 
detection) and a high immunity to false alarms and the detection of small 
animals. The detector includes an Anti-masking function – protection 
against covering the view and it also has two tampers (front and back) 
built in. They immediately report opening the detector or attempting 
tampering. The detector should be installed by a trained technician with  
a valid certificate issued by an authorised distributor. 

Installation 

Conditions: 
1.  The detector has to be installed onto a vertical wall (in a position 

where its bottom surface is parallel to the watched zone). 

2.  The detector should be installed 0.8 – 1.2 m above the ground. 
3.  The best movement detection is provided when the detection beams 

intersect. 

4.  No other moving objects (bushes, trees, high grass, air-conditioners, 

etc.) should be situated in the field of view of the detector. 

5.  Avoid direct effects by strong sources of light (sun reflections, etc.). 
  

 

 

 

Procedure: 

1.  Unscrew  the  locking  screw  on  the  bottom  of  the  upper  cover  

of the detector (1) and remove the detection part’s cover (1). 

2.  Unscrew the 2 screws which hold the detector´s main board (2) 

and  pull  it  out  by  tilting  as  you  pull  it  out.  There  is  also  a  radio 
transmitter glued onto the rear side of the detector´s PCB. 

3.  Remove the rear box cap (5) by pulling it up. 
4.  Unscrew  the  2  screws  which  link  the  rear  cover  (3)  with  the 

mounting plate (4). 

5.  The detector can be mounted onto a level mounting place by the 

2  screws  through  the  mounting  plate  (4).  Or  it  can  be  mounted 
on a pole by metal ties (not supplied). 

6.  Put the detector parts back together in the opposite order when 

it´s finally fixed to the mounting place (4). 

 

 

Warning: Do not touch the detector sensing face 

during handling

 

If it does happen, it´s necessary to clean it up by a 

cotton swab dipped in alcohol.

 

1

2

3

4

5

 

Fig. 1.: 1 – front cover, 2 – detector main board, 3 – rear cover,  

4 – mounting plate, 5 – rear cover cap 

 

 

Fig. 2.: Detector installation. Standard wall installation and fixing by ties.

 

Enrolling the detector to the system 

The signal transmitter for wireless communication is located under 

the main board part of the detector. The batteries are inserted into the 
battery  holder  placed  on  the  transmitter  PCB. 

Use  two  CR123A 

(3 V, 1500 mAh) lithium batteries from the same manufacturer and 
replace  both  batteries  at  the  same  time.

  The  correct  position  of  the 

batteries is indicated on the battery holder. 

 

Enrollment procedure to the system: 

a.  Go  to  the 

F-Link

  software,  select  the  required  position  in  the 

Devices

  window  and  launch  the  enrollment  mode  by  clicking  on 

the 

Enroll

 option.

 

b.  Insert  the  batteries  (mind  the  correct  polarity).  When  the  first 

battery  has  been  inserted  into  the  battery  holder  an  enrollment 
signal  is  transmitted  to  the  control  panel  and  the  detector  is 
enrolled to the selected position. 

c.  Assemble  the  detector  in  opposite  order  to  which  it  was 

disassembled. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 3 - Transmitter:

 

1 – terminals for connection to the detector,  

2 – red indication LED; 3 - yellow indication LED; 4 - battery holder;  

5 – external antenna connector; 6 – production code

 

Notes: 

There  must  be  a  JA-110R  radio  module  installed  in  the  control 
panel. 

The detector can also be enrolled into the system by entering its 
production  code  (9)  in  the  F-Link  software.  You  can  find  the 
production code on the sticker, glued onto the PCB. All numbers 
under the bar code shall be entered (1400-00-0000-0001). 

If  needed  the  transmitter  can  be  equipped  with  an  AN-868 
(3 PIN) external antenna connected to the connector (5). 

Normal operating mode 

The  detector  sends  a  radio  signal  about  activation  when  it  is 

triggered.  In  the  case  of  tampering  with  the  detector  or  tearing  the 
detector  off  its  position  the  detector  sends  a  tamper  signal.  Every 
9 minutes a status report is sent to the control panel. 

Replacing the batteries 

The  detector  checks  its  battery  status  automatically  and  if  the 

batteries are running low it informs the system. The detector remains 
fully  functional.  The  batteries  should  be  changed  as  soon  as 
possible. 

Before battery replacement 

the control panel has to be switched 

to  service  mode  (see  installation  manual  of  the  control  panel)  and 
then  it  is  possible  to  open  the  cover  of  the  detector.  Always  use 
CR123A (3V, 1500 mAh) batteries. 

 Setting up the optical part of the 

detector 

The  optical  part of  the  detector  includes 2  PIR  sensors  with  AND 

logic.  They  detect  movement  in  two  planes.  The  detecting  angle  of 
the lower PIR sensor can be adjusted. The alarm signal is triggered if 
only both detecting planes are triggered at the same time. By shifting 
the lens set up the tilt of the lower detecting plane according to the 
following picture and table. 

 

Fig. 4. 

 
 
 

Отзывы: