background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

The JA-152J MS Bi-directional two-button keyfob 

The JA-152J MS Bi-directional two-button keyfob 

1 / 2 

MMJ54102 

The JA-152J MS is a component of 

the 

JABLOTRON 100 

system. It uses  

bi-directional communication. It is 
designed to remotely control a security 
system, various appliances (using PG 
programmable outputs) or to trigger 
panic alarms and more. The remote 
control can also be enrolled to 
multipurpose relays such as the AC-16x 
series for direct relay control according 
to the pre-set mode. The remote is 
equipped with optical and acoustic 
indication. It checks its battery status 
and indicates when the battery is nearly discharged.

 

Figure:

 1 – LED indication; A, B – buttons,

 see their functions according to 

table 1. 

Enrolling the remote control to a control panel 

There must be a JA-11xR radio module installed in the control panel for 

the ability to work with a control panel. It occupies one position in the system. 

The  remote  can  be  enrolled  to  an  arbitrary  number  of 

JABLOTRON 100  systems.  One  pair  of  buttons  can  control  several 
sections at the same time (common control) and it can show the current 
status of the section or PG output. 
1.  The control panel has to be in service mode. 
2.  Basic procedure: 

a.  Go  to  the 

F-Link

  software,  select  the  required  position  in  the 

Devices

 tab and launch 

enrollment mode

b.  For  transmission  of  an  enrollment  signal  press  and  hold  buttons 

(A+B)  simultaneously  for  at  least  3 s  (within  this  time  the  yellow 
LED flashes rapidly). 

c.  After 3 s the enrollment signal is sent and confirmed by one long 

yellow  LED  flash.  Release  both  buttons  and  close  enrollment 
mode. 

 

To  set  the  keyfob  to  comply with  security 

grade 2 use F-Link SW, Parameters tab and 
the  option  “Perform  EN50131-1”.  (See  the 
JA-10xK control panel installation manual)

 

Notes: 

  Enrolling  the  remote  control  to  the  system  is  possible  by  entering 

the production code via F-Link software. The production code is on 
the sticker with a bar code glued onto the battery holder inside the 
remote.  All  digits  in  the  production  code  are  required 
(example: 1400-00-0000-0001) 

  If  you  want  to  remove  the  remote  control  from  the  system  (for 

instance  when  someone  has  lost  it),  erase  it  from  the  particular 
address of the control panel. 

Setting the properties 

Perform  settings  using 

F-Link

  software – 

Devices

  tab.  Click  on  the 

JA-152J´s 

Internal settings

.  Then  a  window  appears  automatically 

where you can set the following parameters: 

Functions  of  the  buttons:

  set  a  particular  function  for  the  pair  of 

buttons  A-B  (typically  setting / unsetting,  OFF / ON  switching  of  some 
appliance, etc.) or a function for each single button A, B (gate opening, 
garage  door  opening,  etc.)  and  also  for  a  double  press  of  the  remote. 
See the following table 1. 

 

Reaction for single button 

/

  (A / B) 

Reaction for pressing 

simultaneously 

+

  (A + B)

 

x

 

None (button not used) 

x

 

Copy PG 

x

 

Change PG state 

x

 

Silent panic ***) 

x

 

Audible panic ***) 

x

 

Health troubles 

x

 

Report A, B, C, D 

x

 

None (button not used) 

x

 

Read status *) 

x

 

Copy PG **) 

x

 

Change PG status 

x

 

Silent panic ***) 

x

 

Audible panic ***) 

x

 

Health troubles 

x

 

Report A, B, C, D 

Reaction for pair of buttons (segment function) 

 

-

 

 (A - B) 

x

 

Unset / Set 

x

 

Unset / Partially set 

x

 

Unset / Partially set / Set 

x

 

Unset / Set with confirmation 

x

 

Unset / Partially set with confirmation  

x

 

Unset / Partially set / Set with confirmation 

x

 

PG OFF / ON 

Table 1. Button function options overview 

For each function selected for a remote control button it is necessary 

to select the appropriate PG or sections to be controlled or from which 
reports  should  be  reported  (panic,  etc.).  For  the  common  control  of 
multiple sections it 

is not recommended

 to operate a common section, 

but to select the desired section in the remote control internal settings. 

Notes: 

*)  

If  there  is  a  pre-set  function  for  the  pair  of  buttons  A+B  (typically 
Unset / Set section or PG OFF / ON), then that option also triggers 
the  option 

„Read status“

.  If  this  option  is  enabled  the  remote 

reacts  to  a  double  press  by  showing  the  current  status  of  the 
section or PG. 

**)   The 

„Copy PG“ 

reaction  to  a  double  press  can  be  used  for  a  1 s 

impulse  only  for  the  selected  PG – double  button  pressing  cannot 
send 1s activation signal repeatedly unlike single buttons. 

***)  The  reactions  of  the  buttons  which  are  not  supported  when  the 

system is configured comply with security grade 2. 

For  all  functions  related  to  setting  the  sections,  the  control  panel 

obeys the option 

Ways of setting

 selected in the Parameters tab. 

a.  For 

„with confirmation“ 

types  of  setting  (see  table  1),  for 

„set 

with warning“ 

options  and 

„set with confirmation“ 

pressing  the 

buttons in an 8 s period

 

can be repeated and the command is 

performed. 

b.  The  option  „

Do not set with active zone“, 

doesn´t  allow  the 

system  to  be  set  using  a  remote  control  (keyfob)  when  any 
zone  with  an 

Instant

  reaction  is  active.  To  set  the  system  all 

zones / detectors have to be in standby. 

  When  the  button  on  the  remote  control  is  pressed  permanently 

(valid  for  the  „Copy  PG“  function)  activation  is  sent  continuously 
every 1 s. The function can be used for the extension of the impulse 
of a PG output (the chosen PG output has to be set to the function 
„Copy“). Maximum length of keeping the activation is 1 minute. 

Take over a user´s access privileges:

 Taking over a user´s access 

privileges  for  the  sections  and  time  limited  access  according  to  the 
specific user, it respects individual access to the controlled section and 
also limited access to a section if pre-set. Factory settings: disabled. 

Take  over  a  user´s  identity:

  The  selected  user  will  be  visible  as  a 

source in the event log. Factory settings: disabled. 

Delayed panic:

 Valid for reactions such as Silent panic and Audible 

panic. The delay can be set from 5 to 240 s. Cancelling the panic alarm 
during  a  running  delay  can  be  performed  by  repeated  pressing  of  the 
specific button. 

Operation with a multipurpose relay (MPR) 

The remote control can also be enrolled to a multipurpose relay of the 

AC-16x  series,  to  control  a relay  according  to  the  chosen  mode.  Each 
button should be enrolled to the MPR with a different mode. Even one 
remote  can  be  enrolled  to  multiple  MPRs  for  example  with  a  different 
function. When you enroll a keyfob to the control panel and also to an 
MPR  within  its  RF  range,  don´t  select  the  same  buttons.  To  enroll  a 
keyfob to an MPR, follow the installation manual of the MPR. 

Locking the keyfob 

The  remote  control  buttons  can  be  locked  (blocked)  against 

accidental pressing. Locking is disabled by default, pressing any button 
triggers its function immediately.  

If  the  buttons  are  locked,  a  control  panel  command  is  sent  when  a 

button  is  pressed  2x  quickly  (2x  per  1 s)  it  is  also  valid  for  the  panic 
function. 

Caution:  When  a  reaction  for  pressing  buttons  (A+B) 

simultaneously  is  set  (for  example  a  panic  alarm  or  garage 
door  control),  it  is  necessary  to  mind  that  the  action  is 
performed first. 

The 

lock  can  be  activated 

by  simultaneously  pressing  and  holding 

the pair of buttons (A+B) until the yellow LED (1) starts flashing, usually 
in 3 s. When the yellow LED (1) is flashing release button (B) and press 
it  again.  Activation  of  the  lock  function  is  performed  and  confirmed  by 
double  flashes  of  the  yellow  LED  and  a  double  beep.  After  this 
confirmation release all buttons. 

The 

lock  is  deactivated 

by  repeating  the  procedure  above. 

Deactivation of locking is confirmed by one flash of the yellow LED and 
one beep. 

Acoustic indication 

Acoustic  indication  can  be  completely  disabled.  The  default  is 

enabled. When any button is pressed it is followed by a short acoustic 
signal according to the table 2. 

Caution:  When  a  reaction  for  pressing  buttons  (A+B) 

simultaneously  is  set  (for  example  a  panic  alarm  or  garage 

 

 

The  control  panel  is  able  to  run  a 
maximum  of  5  simultaneous  timers 
(delayed panic alarms). 

Отзывы: