JA-110N Bus power output module PG 

The JA-110N is a component of the 

JABLOTRON 100 

system.  

It provides an output power relay switch. It can be used for 
switching on/off the lights, ventilators, etc. The relay can be 
controlled with a programmable control panel (PG) output or 
according to the status of a section (armed = relay on) or when 
there is an alarm in a chosen section (alarm = relay on). The device 
should be installed by a trained technician with a valid certificate 
issued by an authorized distributor.

 

Installation 

The module shall be installed into the JA-190PL mounting box.

 

 

figure:  1 – digital bus terminals; 2 – red relay switching indicator;  

3 – configuration switch; 4 – output relay; 5 – relay terminals 

 

1. 

Use the switch (3) to set the required number of the PG output or 
the number of the section to which the relay should react (see 
tables). 

 

2. 

Connect bus wires to the terminals (1). 

 

 
 

 

When connecting the module to the 
system digital bus, always switch the 
power off. 

 

If the module is installed outside the 
protected area, the JA-110T bus insulator 
should be used for the external section of 
the wiring. 

 

Electrical devices can only be 
connected by an authorized 
technician.

 

 

3. 

Switch on the system and test its functioning. 

 

4. 

Check the supply voltage at the bus terminals (red, black) when 
the relay is activated. The voltage must be at least 9V.

 

5. Connect the controlled device to the relay output terminals (5). 
 

Notes: 

- The module does not occupy any position in the control panel  

(it is not enrolled into the system).

 

-  If you connect multiple modules with identical settings to the bus, 

the relays will have the same function. 

 

-  The number of modules is only limited by the power consumption 

from the digital bus.

 

The setting of individual programmable 

outputs is done in the 

PG 

outputs

 window in the F-Link program

A detailed description of 

the setting is available in the control panel installation manual.

 

-  When the output is set according to the SECTION SET table the 

relay is on if the section is fully armed.

 

-  When the output is set according to the SECTION ALARM table 

the relay is on if there is external or internal warning (EW or IW).

 

 

 

Table 1: The relay reacts to the PG output state 

 

 

Table 2: The relay reacts to arming 

the choosen section  

Table 2: The relay reacts to an 

alarm in the choosen section  

Technical specifications 

Power 

from control panel digital bus 12 V (9…15 V) 

Current consumption in standby mode (relay off / on)  5 mA / 45 mA 
Current consumption for cable choice 

 45 mA 

Relay contact rating  
   

Maximum voltage  

250 V AC / DC 

Re

VLVWLYHORDGFRVij 

  

max. 16 A / 250 V AC 

   I

QGXFWLYHFDSDFLWLYHORDGFRVij 

 

 max. 8 A / 250 V AC 

Minimum acceptable relay output through-wattage(DC) 

0.5 W 

Protection                                                               

Class II 

Dimensions 

78 x 40 x 20 mm 

Classification Grade 

II 

according to  

EN 50131-1, EN 50131-3 

Operational environment according to EN 50131-1 

II. Indoor general 

Operating temperature range 

-10 

°C

 to 40 

°C

 

Also complies with 

EN 50130-4, EN 55022, EN 60950-1 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-110N 
module is in compliance with the essential requirements and other 
relevant provisions of Directive 2004/108/(EC and 2006/95/EC.  
The original of the conformity assessment can be found at 
www.jablotron.com - Technical Support section

 

 