JA-14K(R) Security System Control Panel
45 / 72
MNX22101
Section
– defines which sections may be defined by the user (administrator). The Administrator may also set
codes and tags of users in the assigned sections. A section cannot be assigned to a user that is only authorized
to control PG outputs.
PG
– defines which PG outputs the user is authorized to control (if authorization is required for the output
control).
Disable
– possibility to block a user. The users at position 0 (service technician), 1 (chief administrator)
and 2 (ARC technician) cannot be disabled. Disabling a user is indicated by a red dot. The Administrator (using
the keypad) and Service Technician (via N-Link) are authorized to disable users.
Note
– makes it possible to describe a user’s details, e.g. authorization of access outside working hours etc.
10.5 PG outputs tab
It is used to set functions and links of the programmable outputs. It includes 4 positions. To make changes in
this tab you do not need to be in the Service mode.
Name
– identification of the output (e.g. Garage door…)
Function
– determines behaviour of the output after activation.
Impulse
enables activation with a time limitation (the time is set in the Time button).
ON/OFF
the enabling command will cause activation, disabling command deactivation while
the status of the source or duration is not checked, the last command always
performs its request
Copy
copies activation of a detector or internal status; if there is a request from two
devices, the OR logic is used
Time
– setting of time for the functions Impulse. Time is set in the format
hh:mm:ss
in the range of 00:00:01
to 23:59:59.
Activation
– Opening the Activation Map of the PG output – see chapter 10.5.1 Activation Map of a PG outputs.
Blocking of PG outputs
– makes it possible to block an output by a section
status or detector or other PG output. The blocking prevents the particular PG
from being enabled and if it is already on, it will disable it. In the case of
blocking by a section status you can select whether the blocking is valid when
the section is set or unset and in the case of blocking by a device whether by
its activation or deactivation. Both the blocking options (by a section and
device or by a section and PG output) can be used at the same time.
Reports –
when supplementary GSM communicator is connected then it
allows you to set text of reports and text commands to activate and deactivate
a PG output by phone. Reception of the respective SMS has a similar effect as pressing the functional button
pre-set to the Set or Unset function on the keypad. To control outputs use SMS in the format
code_command
,
e.g.
2345_enable_light
(note: the _ character is a blank space). The code before the command is not obligatory
if in the
Communication
tab /
JA-190Y settings
the “
No code for voice menu and control SMS
” item is enabled
and the phone number of a user authorized to control the corresponding PG output is identified.
PG Disable
– possibility to block a PG output. Disabling (blocking) of an output is indicated by a red dot.
The Service Technician (using N-Link) are authorized to disable an output.