background image

 

 

- 3 - 

MLO51206 

 

Description 

Azor is a wireless alarm for monitoring against burglars. It has been designed for small 

houses, flats, offices, shops, etc. It can also be supplemented with a optical smoke detector. 

Guarding can be simply SET or UNSET using an RFID tag. You just need to press the 

switch at the door and use the RFID tag. The system can also be controlled with a telephone 

– via voice menu options. 

When an alarm is triggered, Azor can  call a security agency  (Alarm Receiving Centre). 

However, it can also report events by SMS messages and by phone calls. You can define 

which information you are interested in (alarms, power supply failure, who set or unset the 

system and when, etc.). 

If you decide to adjust Azor’s behaviour to suit your needs, you just need to connect it to a 

PC and use the included user-friendly A-Link software. 

Features: 

 

 

up to 10 wireless detectors

 (motion, door opening, window opening, fire, panic) 

 

 

up to 10 users 

authorized to control the setting/unsetting 

 

voice menu 

for control via a telephone 

 

SMS and voice reporting of events 

to users

 

(individual settings) 

 

transmission of information to an Alarm

 

Receiving Centre

 (including connection 

checks) 

 

possibility of listening in 

on the guarded premises 

 

siren

 to scare burglars (silent alarm can be set as well) 

 

tamper alarm for 

reporting an attempt to damage any part of the system  

 

1 year battery lifetime 

(in detectors and remote controls) 

 

 

backup battery 

in the communicator (for power failures) 

 

automatic checking 

of the functioning of all parts of the system (including battery 

status checks) 

 

USB port 

for connection to a PC (setup does not require SW installation) 

 

event memory 

of up to 1000 events 

 

false alarm filter 

 

 

optional door opening “chime“ function

 

 

optional wireless doorbell button function 

 

 

services of 

www.myjablotron.com 

 

future 

product updates for new functions

 

 

meets EN-50131-1

, security grade 1, environment class I 

 

 

 

Содержание Azor

Страница 1: ...MLO51205 1...

Страница 2: ...ent of a telephone 12 Communication test 13 Control 14 Switching Azor on off 14 Setting Azor 14 Unsetting Azor 15 Alarm 15 Listening in 16 Informative SMS 16 Settings 17 Computer connection 17 Firmwar...

Страница 3: ...10 wireless detectors motion door opening window opening fire panic up to 10 users authorized to control the setting unsetting voice menu for control via a telephone SMS and voice reporting of events...

Страница 4: ...LO51206 4 AZOR kit contents AZ 10K GSM control unit The GSM control unit a wireless alarm control panel processes information from all detectors in the system It is usually installed in a hidden place...

Страница 5: ...5 MLO51206 AZ 10D RFID tag reader Serves for setting and unsetting It is usually installed at the entrance door AZ 10M door opening detector Reports opening doors windows etc...

Страница 6: ...MLO51206 6 AZ 10P motion detector Reports human motion...

Страница 7: ...llation Attach the detector to a door frame solid part the antenna should point upward Attach the magnet to the door if it is made of metal use a plastic pad underneath When the door is closed the mag...

Страница 8: ...til the indicator light turns off calibration is completed and test whether the detector reacts to human movement Detected motion is indicated with flashing You can test for 5 minutes and then the ind...

Страница 9: ...led in an embedded box insert the magnet in the top frame of the reader Connect the batteries and close the reader the LED indicator should be at the top Switch on the GSM control unit and test its fu...

Страница 10: ...arrow C 6 Connect the power adaptor D 7 Press the GSM control unit button E and hold it for about 2 seconds Azor will light up 8 Wait until all three green LED indicators light up 9 If any of the LED...

Страница 11: ...5 minutes In the case of power trouble the LED indication is always on Neither other electronic appliances nor low current cabling should be near the GSM control unit e g audio systems antenna cables...

Страница 12: ...ccess the menu repeatedly just call Azor again from the same telephone number Tips and specifications Only one telephone without a hidden number can be enrolled Azor must be unset in order to enroll t...

Страница 13: ...t confirming detector activation check Whether the detector batteries have been installed properly Whether radio communication is shielded by a metal obstacle Whether the distance between the detector...

Страница 14: ...er beep Tips and specifications The system can also be set via the telephone voice menu A different exit delay can be set see the Settings If you press the RFID tag reader button in a set state a red...

Страница 15: ...RFID tag corresponding to the user its phone number must be used Alarm When an alarm is triggered the system informs the ARC immediately It concurrently activates a siren sends alarm SMS messages to u...

Страница 16: ...errupted automatically If the listening in is started during the alarm the siren is blocked and reports are sent immediately after the end of the call Informative SMS You can request sending an inform...

Страница 17: ...etup page can be blocked In such a case ask the ARC operators to help you change the settings If you protect the settings with a code in the Settings window Azor will require the code every time a com...

Страница 18: ...ssful enrollment the registration code will be displayed in the field Note Azor uses special security RFID tags No other RFID tags can be enrolled AZ 10M door opening detector Besides detecting door a...

Страница 19: ...ement in the premises Low battery indication When the detector batteries are low Azor sends an informative message Besides that the detector LED flashes when movement is detected outside test mode AZ...

Страница 20: ...Warning Never test the detector by starting a fire inside the premises Tips and specifications The detector cannot be fixed in the base until all three batteries are inserted The smoke detector must...

Страница 21: ...lows 1 Unset Azor 2 Disconnect the power adaptor from the GSM control unit 3 Open the backup battery cover and disconnect the battery 4 Press and hold the GSM control unit button 5 Connect the power a...

Страница 22: ...ection angle 120 covers an area of 10 x 10 m Dimensions 65 x 95 x 60 mm AZ 10M door opening detector Power supply 2x AAA 1 5 V 1200 mAh alkaline batteries lifetime is approx 1 year Reacts to the magne...

Страница 23: ...EN 55022 ETSI EN 301 489 7 EN 60950 1 Can be operated according to ERC REC 70 03 JABLOTRON ALARMS a s hereby declares that the AZ 10K is in a compliance with the relevant Union harmonisation legislat...

Страница 24: ...a warning beep and sends an informative SMS with a tamper warning The siren is not activated though The SMS report is sent only when the cover is open for the first time If you open the same detector...

Страница 25: ...25 MLO51206...