background image

 

MLO51206 

- 14 - 

 

 

Control 

The following description applies to Azor’s default settings. However, you can adjust its 

behaviour as you wish – see the Settings. 

A RFID tag reader

 is usually used to control Azor at the protected premises

Users whose 

telephone has been enrolled to the system can also control Azor via the voice menu.  

The access to the menu can be protected with a personal User’s code – see the Settings. 

Switching Azor on/off 

Azor can be switched on/off by holding the GSM control unit button. Azor reports  

its switching on/off (to the ARC and also with an SMS message). 

 Setting Azor 

 

  Press the SET button on the RFID tag reader (A) and scan the RFID tag (B)  

  The red LED indicator in the reader lights up and a 1 minute exit delay is launched 

  Detector activation will not trigger an alarm in this time  

  Azor will confirm its setting with a longer beep 

 

Tips and specifications 

 

 

  The system can also be set via the telephone voice menu. 

  A different exit delay can be set (see the Settings). 

  If you press the RFID tag reader button in a set state, a red LED indicator lights up. 

  When a detector is activated in the set state, an alarm is triggered. However,  

a  30-second  entrance  delay during which the user can unset the system is launched first (a 

different delay can be set or it can be disabled for individual detectors – see Settings). 

  If there is any unauthorized manipulation of any part of the system in the set state, a tamper 

alarm is triggered. 

  If the user has enabled SMS reporting when the system is set, no report is sent to them if they 

set the system themselves by own remote control or RFID tag. An RFID tag marked by a colour 

label on it is for the user whose phone number was enrolled as the first one. No setting is 

reported when it is cancelled during the exit delay. This reduces unnecessary SMS messages if 

you forget something when exiting the place and you have to return for it. 

Содержание Azor

Страница 1: ...MLO51205 1...

Страница 2: ...ent of a telephone 12 Communication test 13 Control 14 Switching Azor on off 14 Setting Azor 14 Unsetting Azor 15 Alarm 15 Listening in 16 Informative SMS 16 Settings 17 Computer connection 17 Firmwar...

Страница 3: ...10 wireless detectors motion door opening window opening fire panic up to 10 users authorized to control the setting unsetting voice menu for control via a telephone SMS and voice reporting of events...

Страница 4: ...LO51206 4 AZOR kit contents AZ 10K GSM control unit The GSM control unit a wireless alarm control panel processes information from all detectors in the system It is usually installed in a hidden place...

Страница 5: ...5 MLO51206 AZ 10D RFID tag reader Serves for setting and unsetting It is usually installed at the entrance door AZ 10M door opening detector Reports opening doors windows etc...

Страница 6: ...MLO51206 6 AZ 10P motion detector Reports human motion...

Страница 7: ...llation Attach the detector to a door frame solid part the antenna should point upward Attach the magnet to the door if it is made of metal use a plastic pad underneath When the door is closed the mag...

Страница 8: ...til the indicator light turns off calibration is completed and test whether the detector reacts to human movement Detected motion is indicated with flashing You can test for 5 minutes and then the ind...

Страница 9: ...led in an embedded box insert the magnet in the top frame of the reader Connect the batteries and close the reader the LED indicator should be at the top Switch on the GSM control unit and test its fu...

Страница 10: ...arrow C 6 Connect the power adaptor D 7 Press the GSM control unit button E and hold it for about 2 seconds Azor will light up 8 Wait until all three green LED indicators light up 9 If any of the LED...

Страница 11: ...5 minutes In the case of power trouble the LED indication is always on Neither other electronic appliances nor low current cabling should be near the GSM control unit e g audio systems antenna cables...

Страница 12: ...ccess the menu repeatedly just call Azor again from the same telephone number Tips and specifications Only one telephone without a hidden number can be enrolled Azor must be unset in order to enroll t...

Страница 13: ...t confirming detector activation check Whether the detector batteries have been installed properly Whether radio communication is shielded by a metal obstacle Whether the distance between the detector...

Страница 14: ...er beep Tips and specifications The system can also be set via the telephone voice menu A different exit delay can be set see the Settings If you press the RFID tag reader button in a set state a red...

Страница 15: ...RFID tag corresponding to the user its phone number must be used Alarm When an alarm is triggered the system informs the ARC immediately It concurrently activates a siren sends alarm SMS messages to u...

Страница 16: ...errupted automatically If the listening in is started during the alarm the siren is blocked and reports are sent immediately after the end of the call Informative SMS You can request sending an inform...

Страница 17: ...etup page can be blocked In such a case ask the ARC operators to help you change the settings If you protect the settings with a code in the Settings window Azor will require the code every time a com...

Страница 18: ...ssful enrollment the registration code will be displayed in the field Note Azor uses special security RFID tags No other RFID tags can be enrolled AZ 10M door opening detector Besides detecting door a...

Страница 19: ...ement in the premises Low battery indication When the detector batteries are low Azor sends an informative message Besides that the detector LED flashes when movement is detected outside test mode AZ...

Страница 20: ...Warning Never test the detector by starting a fire inside the premises Tips and specifications The detector cannot be fixed in the base until all three batteries are inserted The smoke detector must...

Страница 21: ...lows 1 Unset Azor 2 Disconnect the power adaptor from the GSM control unit 3 Open the backup battery cover and disconnect the battery 4 Press and hold the GSM control unit button 5 Connect the power a...

Страница 22: ...ection angle 120 covers an area of 10 x 10 m Dimensions 65 x 95 x 60 mm AZ 10M door opening detector Power supply 2x AAA 1 5 V 1200 mAh alkaline batteries lifetime is approx 1 year Reacts to the magne...

Страница 23: ...EN 55022 ETSI EN 301 489 7 EN 60950 1 Can be operated according to ERC REC 70 03 JABLOTRON ALARMS a s hereby declares that the AZ 10K is in a compliance with the relevant Union harmonisation legislat...

Страница 24: ...a warning beep and sends an informative SMS with a tamper warning The siren is not activated though The SMS report is sent only when the cover is open for the first time If you open the same detector...

Страница 25: ...25 MLO51206...