The AC-82 wireless relay output module 

 

MJT51202 

1

The AC-82 wireless relay output module  

The  AC-82  is  a  component  of  Jablotron’s  Oasis  JA-80  system.  It  is 
mains-powered  (230V  AC)  and  it  provides  2  relays  which  can  be 
controlled by radio signals and offers the following: 

  Remotely controllable relay outputs which follow JA-80 control 

panel programmable PG outputs  

  Remote control of appliances using RC-8x controllers   

  Relay output of JA-8x wireless detectors 

  Relay output of TP-8x wireless thermostats 

 

1

2

3

4

R

A

D

IO

m

a

x

 F

 5

 A

 /

 25

0

V

buttons

LEDs

fuse

max 5 A

X

Y

 

Installation  

Installation of this module shall only be undertaken by technicians holding a 

certificate issued by an authorized distributor.

.   

Warning: this device is galvanically connected to the mains.  

Open  the  module’s  cover  (1  screw)  and  take  out  the  circuit  board  (2 
tabs). Install the back part of the housing to the desired place, re-install 
the  circuit  board,  connect  the  wires  and  enroll  the  desired  wireless 
devices. 

Terminals 

L,N 

Power: 230V AC/50Hz 

COM 

Common terminal for the output contacts X and Y (fused by a 5 
Amp fuse) 

RE1 

Normally open relay X contact 

RE2 

Normally open relay Y contact  

 

The enrollment of transmitters 

The  X  and  Y  relays  are  totally  independent.  Jablotron  Oasis  devices  with 

transmitters can be enrolled to them individually using the X and Y enrollment 
buttons. Each relay offers 4 different enrollment modes (1 to 4, see the following 
table).  The  reaction  of  a  relay  to  a  transmitter  signal  depends  on  which 
enrollment mode the transmitting device has been enrolled to. 

 

Enrollment procedure 

  Use the X or Y button depending on which relay you want to enroll a device 

to. 

  Repeatedly  press  the  relevant  X  or  Y  button  to  select  the  desired 

enrollment mode 1 to 4 as indicated by the flashing of corresponding LEDs 1 
to 4 (see the table for guidance on choosing the right enrollment mode). 

  Activate the transmitter while the LED is flashing, as follows: 

o

 key fob – press a button 

o

 detector  or  thermostat  –  connect  its  battery  up  (if  it  has  already  been 

connected, first disconnect it,  and then wait 10 seconds) 

o

 Control panel PG output  – key in 299 in service mode  

  Enrollment is confirmed by a short flash from all the AC-82 indicators 

  If no enrollment signal has been received within 10 sec., enrollment mode 

automatically ends. 

  If you wish to enroll another device, repeat the above enrollment procedure. 

Notes: 

  If a device  does not enroll,  either it is too far from the receiver, or there  is 

another  device  already  enrolled  which  cannot  be  combined  with  the  new 
one, or the maximum number of devices has been exceeded. 

  Each device can have its own individual reaction (it is possible to combine 

different reactions for a single relay = enrolling different devices in different 
enrollment modes to the same relay). 

  The  relay  always  performs  the  last  received  instruction  (e.g.  if  the  relay  is 

already on and a signal for a 2 minute pulse is received, the relay will stay 
on for another 2 minutes and then it will turn off). 

  Each  transmitting  device  (keyfob,  detector,  control  panel,  etc.)  can  be 

enrolled to an unlimited number of different receivers. 

  Devices are enrolled to a non-volatile memory, so the AC-82 will not forget 

them if its power is disconnected 

 

Use with RC-8x remote controllers 

  Up to 60 remote controllers can be enrolled to each relay. 

  To operate garage door or parking gate actuators,  use the 1 sec. pulse 

mode  and  connect  the  NC  relay  contact  to  the  push  button  input  of  the 
actuator unit.   

 

Use with JA-8x wireless detectors 

 Detectors can be enrolled to pulse modes 1 and 2 (up to 60 detectors to each 

relay). The 2 minute mode is suitable for automatically switching on lights, 
ventilators
 etc. 

 If a detector(s) is enrolled in mode 3, then the relay will be switched if the 

detector’s tamper sensor is triggered. In this mode up to 8 detectors can be 
enrolled  to  a  single  relay  (which  will  be  switched  if  any  of  the  detectors  is 
tampered with), but no other kind of device can be enrolled, only detectors. 

 If a detector(s) is enrolled in mode 4, then the relay triggers if the detector’s 

No.  Reaction 

Device 

Enrollment method 

Max. 
number 

Notes 

1  1 sec. pulse 

keyfob 

button pressing 

60 

 key fobs and detectors can be combined 

 the relay stays on 1sec, turns off and is then ready to be activated again (the pulse is not 

extended if another 1 sec. pulse activation signal is received while the relay is still on) 

detector 

connecting battery up 

2  2 min. pulse 

keyfob 

button pressing 

60 

 key fobs and detectors can be combined 

 if another 2min. activation signal is received while the relay is on for 2 min., then the relay 

stays on 2 min. more (the 2 minute pulse is extended if re-activated during the pulse) 

detector 

connecting battery up 

Latch  

keyfob 

button pressing 

60 

 impossible to combine keyfobs with detectors 

 * latch = on – off – on – off…. 

 Tamper = on= relay turns on when a detector’s tamper sensor is triggered. 

Tamper = on 

detector 

connecting battery up 

On / off 

keyfob 

button pressing enrolls 
a pair of buttons 

60 

 impossible to combine key fobs with detectors or with a control panel PG output 

PG output of 
control panel 

entry of 299 in Service 
mode  

 impossible to combine PG output with detectors or with keyfobs 

thermostat 

connecting battery up 

 can be combined with keyfobs, detectors and a control panel PG output  

Triggering = on  detector 

connecting battery up 

 impossible to combine detectors with keyfobs or with a control panel PG output 