JabloPCB RP-01 Скачать руководство пользователя страница 1

Contactless access control system RP-01 

1/1 

VAB50202 

Contactless access control system RP-01 

 

 

This device works as a reader of chips (PIT) or cards (PIT). You can 

program it with buttons or PC application. This product provides data 
connection (RS485), therefore it can be used even for industrial 
applications. 
 

1. Technical 

parameters 

 

Operating Voltage   

 

        9 ÷ 16V DC or 8 ÷ 12V AC 

Standby current 

 

 

 

 

         35mA 

terminals NO,C,NC          

output relay – switching contact max. 1A/125V 

operation: 

control unit – II. indoor use (-10°C to +40°C) 

reading unit – outdoor use (IP46) (-30°C to +60°C) 

dimensions (control unit) 

          2,99 in (w) x 4,3 in (h) x 1,299 in (d) 

 
JabloPCB s.r.o.  declares this product is in an agreement with common 
requirements and other related EU regulations. 
The original of the statement is posted at 

www.jabloPCB.cz

 website in 

section  Technical support. 

 

2.   Installation and basic functions RP-01 
 
2.1. Device installation 
 

MOD      SEL       SET

RELE

12

V

NO

C

N

C

Interface RS-485

LCD connector

Setting buttons 

MOD

SEL

SET

Connector

reading device

Output relay

Power

Control unit

Reader unit

 

image no 1 

 

The control unit is designed for an indoor installation. During 

installation please respect placement of the reading unit as it is 
connected with 1m long wire. The reading unit can be placed outdoors. 
 
Warning:  reading unit’s wire can be shortened to 0,5m. Replacement 
with the different one or extension is disabled as device will not function 
correctly. 
 

• 

prior to control unit installation remove the plastic cover   

• 

take an LCD off the control unit by pulling it out – display is 

attached with connector (see image no 1) 

• 

connect the reading unit to the connector (see image no 1) 

• 

check and attach power to the 12V terminals  

• 

place and fit the unit in the desired space 

• 

return LCD back to the original placement (pay extra attention 

to attaching to the connector) 

• 

switch the control unit‘s power on 

• 

you will see a basic initialization on the LCD  

• 

and the unit is ready to be used 

 

2.2. Basic setup 

Unit was already set in the factory and is ready to learn (program) 

individual positions. There are 999 position ava master chip 
position. 

2.3. Unit learning (PIT – chips and cards) 

Programming is possible either with PC controlling software (you 

need to connect interface SW-01) or manually with buttons placed 
under the LCD and instructions on the screen. 
The Master Chip necessary to enter the learning mode is included in 
the package. 
 
Table – reading unit indicator signals 

 indicator 

 

Description 

No light 

Ready to program 

Green light 

PIT was identified and successfully learned 

learning 

Red light 

PIT was already programmed to a different 
position 

No light 

Unit is ready to read PIT 

Green light 

PIT authorized to enter – relay ties 

Pulse 

mode 

Red light 

PIT unauthorized to enter – relay doesn’t tie 

Green light 

Relay OFF 

Red light 

Relay ON 

Switching 

mode 

No light 

Unknown PIT is read and indicator switches off 
for 1s 

 

Manual way: 

 

There are 

MOD

 button and 

Master Chip

 to enter the programming 

mode.Press and hold the 

MOD

 button for at least 2s and display will 

show „

check MASTER

“. On this command place Master Chip on the 

reading unit. Following that you will gain access into the learning mode 
and first available position for programming individual PIT will be 
offered. 
If you don’t want to start learning individual PITs from this position you 
can set any position by pressing the 

SEL

 button.The bottom row on the 

screen displays the position selection options (with each press of the 

SEL

 button). 

SEL

 button setting options: 

Po100

 and consequently every press of SET button – position 

is set for hundreds 100, 200, 300... 

Po10

 and consequently every press of SET button – position is 

set for tens 10, 20, 30... 

Po1

 and consequently every press of SET button – position is 

set for ones 1, 2, 3... 
(settings can be combined. For example you can set 100 then 10 and 3 
= result is learning position 113) 

RELAY time

 – see point 2.5 

DELETE ?

 – current position will be deleted by pressing the 

SET

 button  

Return to the learning mode  

 
Setting of each option is made by pressing the 

SET

 button (it has got a 

repeat function when pressed and held). Press 

MOD 

button to end 

settings. 
To exit learning mode press and hold 

MOD

 button. Device will go into 

standby mode. 
 
It is possible to re-program or delete any position except a learning 
position „

master position“ 

(see point 2.4). 

 
Programming using PC application is more convenient as you can work 
with files like CSV (export from Excel).  The first column has to be a 
learning position and the second column needs to be selected PIT´s 
manufacturing code. Ignore the other possible columns. 

 
Warning:  

During learning new PIT chip on an available position or into an empty 
space (caused by deleted position) follow these instructions. 
Access the learning mode (see point 2.3). When first available position 
is offered, programm PIT by placing it on the Reading Unit. Also you 
can decide which position to use at this stage.  After the process of 
programming the Reading Unit will offer you the next one up position. 

In 

case this position has  already been programmed to a PIT and you 
use this position to learn a new PIT, the previous one will be 
deleted. 

 

 
 

Отзывы: