JR_EYE‐02.ENG.MAN.MANUAL.10.DOCX
‐ 14 ‐
JabloTool WEB can also provide monitoring function for registered users. The EYE‐02 camera can send a
copy of any event record to JabloTool ARC. This will dramatically
speed
up your access to the event list and
provide the backup log of events. This function is available for FREE for users who register at
www.jablotool.com
.
5.4
S
WITCHING
OFF
AND
ON
To switch the EYE‐02 camera OFF
, first, switch it to the
C O N F I G
C O N F I G
mode (see chapt.4.3). Disconnect the
power cable from the camera and press and hold the power button on the back panel for
3 seconds
. When
the green light on the front panel switches off, the camera shuts down and you can release the button.
To switch the EYE‐02 camera ON
, press and hold the power button on the back panel of the camera. Keep
holding the button until the green light on the front panel switches on. The start‐up process has started and
you can release the button.
The camera also starts up automatically after it is connected to the AC adaptor.
Whenever the camera is expected to be switched off for a longer period of time or for transportation, it is
strictly recommended to remove the backup battery from the EYE‐02 camera.
5.5
B
ATTERY
M
ODE
The EYE‐02 camera has an internal backup Li‐Ion battery which allows it to work even in case of the loss of
AC power. The backup battery allows the camera to operate for approximately
24 hours
. The individual
duration of the battery may vary and depends on many factors such as the selected camera profile, number
of events, quality of signal, etc.
In certain cases, for example when used in locations where AC power isn’t available, it may be desired to
extend the battery operation duration. In such case you may use the special
B A T T E R Y
B A T T E R Y
mode.
When in the
B A T T E R Y
B A T T E R Y
mode, the EYE‐02 camera reduces dramatically its power consumption (it logs out
from the GSM network, switches off the short range radio receiver and switches on the motion‐in‐picture
detector only after ALERT). It means that the EYE‐02 camera, while in the BATTERY mode, can not be
reached by calls or by SMS commands. Additionally, the external detectors and remote controls can not be
used.
The EYE‐02 camera keeps all the internal detectors working and reports all events as in the NORMAL mode.
After an ALARM, the EYE‐02 camera switches on the radio and logs onto the GSM network for 2 minutes.
Only during these 2 minutes does it react to calls, SMS commands and remote controls.
A fully charged battery in the
B A T T E R Y
B A T T E R Y
mode can operate the EYE‐02 camera for up to 30 days.
Содержание EYE-02
Страница 1: ...GSM Security Camera EYE 02 ...