The expert for industrial and automotive communication
Manual
iPC-I XC16/PCI
Intelligent PC/CAN Interface
Страница 1: ...The expert for industrial and automotive communication Manual iPC I XC16 PCI Intelligent PC CAN Interface...
Страница 2: ...ts please contact IXXAT in written form by Fax 49 0 7 51 5 61 46 29 e Mail support ixxat de For customers from the USA Canada Fax 1 603 471 0880 e Mail techsupport ixxat com Copyright Duplication copy...
Страница 3: ...on 6 3 Connections and displays 6 3 1 Pin assignment 6 3 1 1 CAN bus connection 6 3 1 2 PCI bus connection 8 3 2 CAN bus terminal 8 4 Firmware update 9 5 Appendix 10 5 1 Support 10 5 2 Returning hardw...
Страница 4: ......
Страница 5: ...signal environment Infineon 16 bit microcontroller with 40MHz clock 512 kByte RAM 128 kByte Flash Data exchange between PC and microcontroller system via 8kB dual port RAM 2 independent CAN lines CAN...
Страница 6: ...remove the mains plug 2 Open the PC according to the instructions of the PC manufacturer and find a suitable slot The interface is designed according to the PC standard and can easily be in stalled t...
Страница 7: ...eved when the shield of the CAN cable is earthed The assignment of the Sub D connector is shown in Table 3 1 As an option the bus connection can be galvanically isolated from the CAN bus Pin no Signal...
Страница 8: ...th the PCI spec ification 2 2 The iPC I XC16 PCI can be operated both in a 3 3V and in a 5V PCI signal environment The maximum PCI bus frequency with which the interface can be operated is 33MHz 3 2 C...
Страница 9: ...flash of the microcon troller The card is always supplied with the latest UCI firmware in the flash The VCI can be operated with this firmware If you require different firmware e g for the CANopen Ma...
Страница 10: ...port section on our website After applying for the RMA number you will receive a return delivery note from us which you should enclose with the return delivery If returns are made with out an RMA numb...
Страница 11: ...d to take back the delivered products at his her expense when no longer used and to correctly dispose of them in accordance with the statutory regulations or to im pose these obligations on the third...
Страница 12: ...d CAN bus terminal resistor none high speed RTH RTL 4 7k low speed CAN run delay with galv isolation typically 32 ns max 50ns CAN baud rates 10 kBaud 1 MBaud high speed 10 kBaud 125 kBaud low speed Ma...
Страница 13: ...ceived including interference that may cause undesired operation Class A digital device instructions Note This equipment has been tested and found to comply with the limits for a Class A digital devic...
Страница 14: ...product iPC I XC16 PCI with the article numbers 1 01 0047 33260 1 01 0047 33110 1 01 0047 33220 do comply with the EC directives 2004 108 EC Applied harmonized standards in particular EN 55022 2006 A1...