Aluminum housing version
2 Aluminum housing version
2.1 Connector
allocation
X1
LED
X2
X3
Fig. 2-1: Connector arrangement aluminum version
2.1.1 Power supply (X1)
The device is supplied with direct voltage of 9 V - 36 V. A pre-fabricated cable for
power supply is included in the scope of delivery. The connection allocation is
shown in Table 2-1.
The CANlink II is protected against polarity reversal, under-voltage and over-
voltage. In the event of polarity reversal or under-voltage, it is switched off, with
over-voltage an internal fuse is triggered.
Pin no.
X1
Signal Lead
color
1 PWR
(+)
White
2 GND
(-)
Brown
3 Shield
Shield
1
1
2
3
Table 2-1: Pin allocation Power
Copyright IXXAT Automation GmbH
CANlink II - Manual, V1.3