20 (32)
6.3
Configuration of Interface Modes (ASCII, VCI, ECI)
The VCI interface mode can only be operated via Ethernet. Configuration is possible via
USB.
Fig. 8
ASCII Gateway Mode
►
Make sure, that the device is connected to the network (see
Connecting Possibilities, p. 15
and to the CAN-Gateway Configurator (see
Connecting the Device in the CAN-Gateway
►
In drop-down list (
1
) select the desired interface operational mode.
►
In the configuration tree (
5
) select
Interface
.
►
If checkbox
Only for specified device
(
6
) is enabled, enter the serial number of the device to
which the configuration can be written.
If ASCII Gateway Mode is selected:
►
Configure the protocol line ending (
4
).
►
Define the IP port (
4
).
►
If checkbox
Expert Mode
(
7
) is enabled, select the desired settings (for more
information see User Manual
CAN-Gateway Configurator
).
►
To write the configuration to the device, click button
Write to
(
3
).
or
►
Click button
Save
or
Save as
(
2
) to save the configuration.
►
To exchange messages in the Gateway mode, use ASCII commands (for more information
see Software Design Guide
CAN@net NT 100/200/420 Generic Protocol for Gateway Mode
►
In the VCI interface mode configure the Device Server (for more information see Installation
Guide
►
In the ECI interface mode see Software Design Guides of the ECI on
for
information about the communication in the ECI mode and commands that are used to
exchange CAN messages.
CAN@net NT User Manual
4.01.0332.20000 1.7 en-US