All appliances must be mounted so that the lowest
point is at least 2.3 m above the floor. The Vent body
and ducted blower is designed to fit a ceiling cavity or
between – floor space with a minimum height of 245
mm. The modules may be installed between joists
using the spring clips (Fig. 2c). Ensure that the outlet of
the Vent unit is directed towards the outer wall. If the
desired orientation of the Vent unit directs the ducting
across ceiling joists ensure that the closest ceiling joist
is not within 150 mm of the Vent outlet.
Note:
Neo Heat Modules (models 36111 & 36112)
must be located at least 1m away from the nearest
wall.
Sufficient air inlet into room
Steam will only be removed if there is sufficient flow of
air through the room. Ensure generous inlets exist
through windows, vents or under the door. Air flow
path from inlet to fan should ideally pass over the
steam sources (see Fig.1).
Bathrooms which have high ceilings, are larger than
average, or have an open shower may all require
additional ventilation. We recommend that you visit our
website for further details and suggestions on
effectively ventilating your bathroom.
Ventilation Requirements
Clearances
Figure 2a
A
: 215 mm
B
: 15 mm min. clearance above unit
Figure 2b
C
: Models: 34101, 34102, 35101 & 35102 - 50 mm
Models: 36111 & 36112 - 75 mm
D
: Models: 34101, 34102, 35101 & 35102 - 195 mm
Models: 36111 & 36112 - 151 mm
E
: Models: 34101, 34102, 35101 & 35102 - 35 mm to
structural member
Models: 36111 & 36112 - 50mm to structural members.
F
: Models: 34101, 34102, 35101 & 35102 - 150 mm.
Figure 2c
Models: 34101, 34102, 35101 & 35102 - 35 mm min.
clearance is required near all joists
Models: 36111 & 36112 - 50 mm min. clearance is
required near all joists
.
For maximum efficiency and fan performance there
a few key points to keep in mind when installing your
Tastic.
are
Fig. 1: Ideal placement of Ventilation units.
Sufficient air inlets into room are required
Fig. 2b: Minimum clearances for installation
Fig. 2a: Minimum blower clearances
Fig. 2c: Minimum clearances for installation
Overview
Electrical Requirements
Fig. 6: Wiring diagram for models 34101 and 34102, Neo Vent n Lite.
See the wiring diagrams on the following pages for supply requirements and maximum loadings for each
model. Modules may be connected to a lighting or power circuit if loading permits. These models are for
wired-in installation and wiring must be carried out by a registered electrician. Switches and a wall plate
are not provided with the hardwired Neo modules. Do not use this product with any solid state speed
control or commercial dimming device.
Neo modules are fitted with LED centre lamps. To ensure
operation and to prolong the life of the LEDs please wire as per
the following wiring diagrams for the appropriate model.
correct
Wiring Diagrams
Fig. 8: Wiring diagram for model 36111 and 36112, Neo Heat.
Wiring – Aust & NZ
In all versions a local isolating switch (not supplied)
must be incorporated in the fixed wiring to the
appliance to allow disconnection of supply during
maintenance. This isolating switch, and the wall
switch, must be located in accordance with Wiring
Rules AS/NZS 3000. They must not be installed where
it can be reached from the bath or shower recess or
enclosure (see AS/NZS 3000 Section 7).
Vent & Vent n Lite models 34101, 34102, 35101 &
35102:
Switch the power outlet for the Inline Blower
with a wall switch (not supplied) as per the Wiring
Diagrams. Do not mount the power outlet for the Inline
Blower more than 200 mm from the Inline Blower.
Wiring – UK & Eire
In all versions a local isolating switch (not supplied)
must be incorporated in the fixed wiring to the
appliance to allow disconnection of supply during
maintenance. This isolating switch, and the wall
switch, must be located in accordance with the
applicable Wiring Rules and it must not be installed
where it can be reached from the bath or shower
recess or enclosure.
Vent and Vent n Lite models 34101, 34102, 35101
& 35102:
Supply should be connected to the Inline
Blower 2-core power lead as per the Wiring Diagrams.
The plug fitted to the power cord is to be cut off and
the wires stripped to allow connection.
The colours of the wires in the Inline Blower 2-core
lead may not correspond to those in the fixed wiring.
The designation of poles for the Tastic power leads are
as follows:
Tastic Wire
Colour
Connect to
Supply Pole
Brown
Live
Blue
Neutral
Fig. 7: Wiring diagram for model 35101 and 35102, Neo Vent.
E
34101 & 34102:
0.4A 50Hz
FASCIA
BODY
M
ACTIVE
NEUTRAL
DUCTED FAN
TERMINAL BLOCK
3 X DOWNLIGHTS
ACTIVE
NEUTRAL
FOR SWITCH
CONNECTION
REFER TO FIGS
9 & 11
FOR SWITCH
CONNECTION
REFER TO FIG
10 & 12
35101 & 35102:
0.3A 50Hz
M
DUCTED FAN
ACTIVE
NEUTRAL
FOR SWITCH
CONNECTION
REFER TO FIGS
10 & 12
36111 & 36112:
3.3A 50Hz
FASCIA
BODY
ACTIVE
NEUTRAL
TERMINAL BLOCK
THERMAL SWITCH 65°C
HEAT LAMP
FOR SWITCH
CONNECTION
REFER TO FIGS
9 & 11
Wiring Diagrams
* This switch must be double-pole
with minimum 3 mm contact gap.
type
A
B
Fig. 3: Layout of Neo Vent and Vent n Lite.
Neo Models: 34101, 34102, 35101 & 35102
Wall switch (not supplied)
Inline Ducted Blower
Ducting
Air outlet grille
positioned in eaves lining
Exterior
of home
Eaves
lining
Vent unit
Flexible support
Cable not on 35101 & 35102
Fig. 9
Fig. 10: Inline Ducted Blower
Fig. 11
Fig. 12: Inline Ducted Blower
A
N
E
Wall Switch (not supplied)
A
N
Wall Switch (not supplied)
A
N
E
Wall Switch (not supplied)
A
N
BROWN
BLUE
Wall Switch (not supplied)