REL1.1
Page 80 of 92
RZ/G1H Qseven SOM Hardware User Guide
iWave Systems Technologies Pvt. Ltd.
3.1.2
Power Input Sequencing
The RZ/G1H Qseven SOM
’s
Power Input sequence requirement is explained below.
Power up Sequence:
•
VCC_RTC must come up at the same time or before VCC comes up.
•
PWGIN signal from Qseven Edge must be active at the same time or after VCC comes up.
Power down Sequence:
•
PWGIN signal from Qseven Edge must be inactive at the same time or before VCC goes down.
•
VCC must go down at the same time or before VCC_RTC goes down.
Figure 9: Qseven SOM Power Sequence
Table 16: Power Sequence Timing
Item
Description
Value
T1
VCC_RTC rise time to VCC rise time
≥ 0 ms
T2
VCC rise time to PWGIN rise time
≥ 0 ms
T3
PWGIN fall time to VCC fall time
≥ 0 ms
T4
VCC fall time to VCC_RTC fall time
≥ 0 ms
Содержание iW-RainboW-G21M
Страница 75: ...REL1 1 Page 75 of 92 RZ G1H Qseven SOM Hardware User Guide iWave Systems Technologies Pvt Ltd ...
Страница 76: ...REL1 1 Page 76 of 92 RZ G1H Qseven SOM Hardware User Guide iWave Systems Technologies Pvt Ltd ...
Страница 77: ...REL1 1 Page 77 of 92 RZ G1H Qseven SOM Hardware User Guide iWave Systems Technologies Pvt Ltd ...
Страница 78: ...REL1 1 Page 78 of 92 RZ G1H Qseven SOM Hardware User Guide iWave Systems Technologies Pvt Ltd ...
Страница 92: ...REL1 1 Page 92 of 92 RZ G1H Qseven SOM Hardware User Guide iWave Systems Technologies Pvt Ltd ...