15. CUSTOMIZED INSTRUMENT PANEL
Using only the components of the panel that are not wired
to allow for panel customization, they will have to be wired
using the 10 meter long wire harness, set up at one end for
coupling to the JB connector and at the opposite end with
conductors with free terminals with identifying numbering
on each wire. The conductors will have to be connected to
the individual components as indicated in the electrical and
wiring diagrams in Chapter 24.
CAUTION
to assure the functionality of the safeties pertaining to the
engine start/stop commands from the instrument panel or
engine room, it is mandatory to wire the key switch strictly
as shown in the electrical diagrams in chapter 24.
The wiring details of the indications and alarms module
alone are provided below; indications for IVECO MOTORS
indicator instruments, are shown in the related wiring dia-
grams in Chapter 24.
JD Connector for indications and alarms module
VIEW FROM THE INTEGRATED SIDE
IN THE REAR PART OF THE MODULE
VIEW FROM THE TERMINAL SIDE
OF THE COUPLING SIDE WIRING
Connector TRIDENT - ITT Cannon
part # TST 24PA00
terminal
female
part # 192990-0050
lid
rear
part # TST24AH00
JD connects the indications and alarms module to the elec-
trical system of the engine (sensors, power supply, etc.).
The terminal part of the wire harness, supplied with the
module, must be completed using female terminals, as
described in the electrical diagram of Chapter 24.
For standard-equipped engines, to have the essential indica-
tions available, the following ways must be wired: 1, 2, 3, 7, 8,
9, 10, 13, 14, 15, 17, 18, 19 with the female terminals supplied
as standard equipment.
Figure 4
Figure 5
13
9
5
1
14 15 16
10 11 12
6
2
4
7
8
3
21 22 23 24
17 18 19 20
04_241_N
1
2
3
4
5
6
8
7
10 9
12 11
13
14
16 15
17
18
20 19
21
22
24 23
05_034_C
Содержание NEF N40-ENT-M25
Страница 64: ...INSTALLATIONDIRECTIVE 64 N40 ENT M25 N60 ENT M37 M40 MAY 2006 ...
Страница 69: ......