installation directiVe
10
N40 ENT M25
N60 ENT M37-M40
MAY 2006
5. TECHNICAL DATA FOR INSTALLATION
n40 ent
m25
n60 ent
m
n60 ent
m40
Combustion and ventilation air when underway
Static vacuum allowed downstream of the air filter
kPa
mm H
2
O
≤
3,5
≤
350
≤
3,5
≤
350
≤
3,5
≤
350
Combustion air flow rate
m
3
/h
≥
900
≥
1050
≥
1150
Engine room ventilation air flow rate (excluding combustion air)
m
3
/h
≥
3100
≥
4700
≥
5050
Static vacuum allowed in the engine room
kPa
mm H
2
O
≤
0,1
≤
10
≤
0,1
≤
10
≤
0,1
≤
10
Temperature allowed in the engine room
°C
≤
50
≤
50
≤
45
Temperature increase in the engine room to ext. temperature
°C
≤
15
≤
15
≤
15
Exhaust gas discharge
Allowed static back pressure
kPa
mm H
2
O
≤
10
≤
1000
≤
10
≤
1000
≤
10
≤
1000
Exhaust gas temperature at maximum power (turbocharger inlet)
°C
650 ± 25
640 ± 25
660 ± 25
Flow rate at maximum power
kg/h
1080
1560
1780
Outer diameter of exhaust mixed with sea water
mm
inches
127
5
127
5
127
5
Fuel supply
Transfer pump delivery at maximum rpm
l/h
≤
250
≤
250
≤
250
Flow rate return to tank
l/h
≤
240
≤
240
≤
240
Fuel temperature to allow maximum power
°C
≤
70
≤
70
≤
70
Inner diameter, intake pipe
mm
≥
8
≥
8
≥
8
Inner diameter, return pipe
mm
≥
8
≥
8
≥
8
Thread on pre-filter junctions
M
14 x 1,5
14 x 1,5
14 x 1,5
Free height below filter to replace filter
mm
≥
30
≥
30
≥
30
Allowed intake vacuum
kPa
mm H
2
O
≤
35
≤
3500
≤
35
≤
3500
≤
35
≤
3500
Allowed on tank return pipe back pressure
kPa
mm H
2
O
≤
20
≤
2000
≤
20
≤
2000
≤
20
≤
2000
Open sea water cooling line
Intake pipeline diameter
mm
inches
45
1,77
45
1,77
45
1,77
Pump delivery at maximum rpm
l/h
12000
12000
15500
Sea water pump height above sea level
m
≤
2
≤
2
≤
2
Allowed intake vacuum
kPa
mm H
2
O
≤
20
≤
2000
≤
20
≤
2000
≤
20
≤
2000
Dry exhaust outer diameter
mm
inches
45
1,77
45
1,77
45
1,77
Allowed engine inclination angles
Maximum longitudinal in continuous operation ( dynamic)
degrees/360
+20
+18
+18
Maximum transverse in continuous operation ( dynamic)
degrees/360
± 22º30'
± 22º30'
± 22º30'
Longitudinal for oil level check with standard dipstick
degrees/360
0 ÷ +6
0 ÷ +6
0 ÷ +6
Содержание NEF N40-ENT-M25