Before going to
Mode 6
please make sure that the “Known
load weight” is ready to be lifted.
The loaded forks must be on the ground
(No hydraulic pressure in the lifting hydraulic circuit)
- Press the
“M”
button to advance to
Mode 6
and immediately lift the
“Known load weight” just above the ground.
- LED display will go blank and within few seconds LED display
will show the value of calibrated “Known load weight of 4000”
Lower the load to the ground.
System will go automatically into operational mode.
System is ready to be used.
Mode digit will display number
8.
Note:
If system is set up for overload alert the
Mode 7
will be shown automatically when loaded forks are
lowered to ground. Follow instruction for overload alert value input.
Weighing calibration function is completed
Lower the loaded forks to the ground.
Integrated Visual Data Technology Inc., 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7