ITW SIMCO ION SS-50 Скачать руководство пользователя страница 1

SS-50 Bars

5200210 Rev. A

SS-50 Super Service  

Static Neutralizing Bars & 

Power Supplies

INSTALLATION AND OPERATING INSTRUCTIONS

Содержание SIMCO ION SS-50

Страница 1: ...SS 50 Bars 5200210 Rev A SS 50 Super Service Static Neutralizing Bars Power Supplies INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...SS 50 Bars 5200210 Rev A This page intentionally left blank ...

Страница 3: ...TION 2 Receipt of Equipment 2 Return Shipments 2 3 SPECIFICATIONS 3 4 INSTALLATION 4 Grounding 4 Mounting Static Neutralizing Bars 4 Mounting Power Supplies 4 Installing High Voltage Cables 4 5 OPERATION 5 6 TROUBLESHOOTING 6 7 MAINTENANCE 7 8 REPLACEMENT PARTS 8 9 WARRANTY 8 ...

Страница 4: ...peration 1 Read instruction manual before installing or operating equipment 2 Only qualified service personnel are to perform installation and repairs 3 All equipment must be properly grounded including the machine frame to which the equipment is mounted CAUTION ELECTRICAL SHOCK HAZARD Always disconnect power supply before connecting or disconnecting static neutralizing equipment Avoid touching st...

Страница 5: ... 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred the local carrier should be notified at once A report should be forwarded to Simco Ion 2257 North Penn Road Hatfield PA 19440 and 215 822 6401 3 Empty the carton to ensure that small parts are not discarded Return Shipments Prior to returning goods contact a Simco Ion Customer Service Representative fo...

Страница 6: ...0V 230V 120V 230V Frequency 60 Hz 60 Hz 50 Hz 60 Hz 60 Hz Output Ports 2 2 4 4 4 SS 50 OperatingVoltage 5 kV AC Humidity 70 RH max no dewing permissible Dimensions 1 2 W x 19 32 H Mounting Studs 6 32 Enclosure Anodized Aluminum Inner Bar Material Teflon Emitter Point Stainless Steel Type 303 ...

Страница 7: ...y to a well grounded metal machine frame or connect a heavy copper wire from the ground terminal of the power supply to a well grounded electrical conduit or water pipe Mounting Static Neutralizing Bars 1 Place each static bar so that it extends across the width of the material to be neutralized 2 The bar s ionization points must face the material to be neutralized 3 For optimum performance mount ...

Страница 8: ...upplies do not require spring loaded cable connectors 4 Ensure that the power supply is de energized and then remove the protective plastic plug from the power supply high voltage connection by gently prying with an insulated screwdriver 5 Insert the cable with spring loaded connector attached into the power supply high voltage connection Screw in the knurled plug to secure the cable NOTE FINGER T...

Страница 9: ...s or other contamination 6 If none of the points are working either the bar or the power supply is defective To identify which is not working De energize the power supply Disconnect all static bars from the power supply by unscrewing the knurled plugs and gently pulling out each high voltage cable Connect an insulated test wire to the power supply s ground stud Energize the power supply Slowly ins...

Страница 10: ...compressed air to remove loose particulate from the static bar If it is very dirty it may be necessary to remove the static bar from its mounting and turn it upside down while using compressed air to clean A soft brush with plastic bristles may be used as well 3 Press a soft pencil eraser onto each point and gently twist to remove any buildup from the ionization points 4 Wipe ionization points and...

Страница 11: ...ost Prior to returning any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed altered has received damage through abuse carelessness accident connected to improper line voltage or has been serviced a...

Страница 12: ...SS 50 Bars 5200210 Rev A Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2021 Simco Ion Printed in the U S A ...