ORBITALUM TOOLS GmbH
D-78224 Singen www.orbitalum.com
[REV. 20200320] OC_GFX_BA_790144761_00__INH-02_EN
60
Set-up and assembly
GFX 3.0, GFX 6.6
eNGLISH
8.4
Saw blade clamping point 1: Fitting the saw blade/bevel cutter
IMPORTANT!
Warning messages are used in these instructions to warn you of possible risk of death, injury
or damage to property. Always read and observe these warning messages! To ensure safe
setting up and mounting please read all the warning messages in chap. 2, p. 40 and chap.
8, p. 56 attentively.
WARNING!
Hot components!
Danger of injury to hands.
X
Wear suitable safety gloves when replacing the saw blade (in accordance with DIN EN
388 and EN 407, see chap. 2.4, p. 42).
X
Lay down the tools and fastening parts rapidly.
Only use saw blade clamping point 1
to cut and bevel
tubes
. If you want to cutting tube elbows, use saw blade
clamping point 2 (chap. 8.5, p. 61).
2
1
NOTe!
Saw blades/bevel cutters can only be fitted or replaced if
no
tube is clamped in the vice. If
necessary, remove the tube before fitting the saw blade.
8.4.1 Inserting the saw blade
1. Turn the tube cutter clockwise and upwards by 180°.
2. Tighten the locking screw (2).
3. Loose the nut (5)
clockwise
(left-hand thread).
4. Clean the saw blade shaft (1) and vicinity with a brush.
5. Place the saw blade (3) and clamping disc (4) onto the shaft (1).
IMPORTANT!
Put the saw blade onto the shaft so that the inscription points to the machine.
The toothing then points in the right direction.
6. Tighten nut (5)
counterclockwise
(left-hand thread).
7. Loosen the locking screw (2).
8. Turn the tube cutter clockwise and downwards to its home position.