ITT NEO-DYN 100T Скачать руководство пользователя страница 7

 

Enclosure 6N Temperature switches

Page 4

  

PROCESS CONNECTIONS 

The process connections are: 

Model 100T: ½” - 14 NPT male standard. The .25 in. (6.4 mm) dia. probe extends 3.0 in. (76 mm) 

past the end of the pipe thread

 

Model 100TC: ½” - 14 NPT male standard. The .38 in. (9.7 mm) dia. probe extends 4.50 

in. (114 mm) min. from the end of the pipe thread, and can be extended an additional 

9.5 in. (241 mm). After this length adjustment, torque the gland nut in the pipe fitting to 

230 ± 20 in-lb (26.0 ± 2.3 newton-meters).. 

When installing the Temperature switch, always: 

 

Make sure that the unit and your system have matching threads. 

 

Use the wrench flats provided. 

 

Seal all joints with pipe joint sealing compound. 

CAUTION 

Avoid excessive torque on all threaded connections

WARNING 

Do not exceed the marked maximum operating pressure in normal operation. 

WARNING 

Do not use as a safety device.

 

 

The marked Proof Pressure is provided to give the maximum allowable pressure without 

causing permanent damage to the temperature switch in the event of an over-pressure 

condition. Set pressure relief/safety valves below this setting. 

PROCESS MEDIA 

Process media must be compatible with the wetted materials listed in Chapter 5. 

Compatibility is defined by an “A” rating in the Chemical Resistance Guide for Metals 

and Alloys, the Chemical Resistance Guide for Plastics, and the Chemical Resistance 

Guide for Elastomers, all published by Compass Publications, and available from the 

National Association of Corrosion Engineers (NACE), Houston, Texas; telephone 281 

228 6200. 

 

 

Содержание NEO-DYN 100T

Страница 1: ...NEO DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610 0012 Rev C...

Страница 2: ...al injury death or substantial property damage if the warning is ignored CAUTION Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored SPECIAL C...

Страница 3: ...FIGURATIONS 2 CHAPTER 2 INSTALLATION 3 MOUNTING 3 PROCESS CONNECTIONS 4 PROCESS MEDIA 4 POTENTIALLY EXPLOSIVE ATMOSPHERES HAZARDOUS LOCATIONS 4 ELECTRICAL CONNECTIONS 5 CHAPTER 3 ADJUSTMENTS AFTER INS...

Страница 4: ...Model 100TC has a graphite filled non asbestos packing Setpoint adjustments are easily made through the adjustable range by turning an adjustment nut located inside the housing The standard configurat...

Страница 5: ...n or our representatives in several ways The Neo Dyn customer service phone number is 661 295 4000 Our customer service department is open from 7 00 am to 3 30 p m Pacific Time Our Internet site is ww...

Страница 6: ...MOUNTING Model 100T can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supporting the weight It can also be attached to a flat su...

Страница 7: ...ling compound CAUTION Avoid excessive torque on all threaded connections WARNING Do not exceed the marked maximum operating pressure in normal operation WARNING Do not use as a safety device The marke...

Страница 8: ...uirements of the NEC or applicable local or national electrical codes including wire gauges and insulation temperature ratings Conduit seals may be required Figure 2 Form C and CC Schematics Shown Bel...

Страница 9: ...below 4 To check the increasing setpoint of a temperature switch insert the temperature probe into a fluid bath so that the hex is within 3 8 inch 9 5 mm of the surface and also insert a calibrated th...

Страница 10: ...ng can be heard to audibly snap but an ohmmeter indicates no electrical switching the cause is probably stuck or burned switch contacts or the switch element has moved away from the position where it...

Страница 11: ...ls CE Mark All models with option letter X in the part number Internal switching elements are recognized components by both UL and CSA Part Number The part number contains information about which conf...

Страница 12: ...rature Ratings Minimum ambient temperature is 40 C 40 F Form C3X SPDT 15 amp 125 or 250 VAC 1 8 HP 125 VAC HP 250 VAC to 70 C 158 F max 5 amp resistive 3 amp inductive 28 VDC 5 amp resistive 04 amp in...

Страница 13: ...rd switches are listed below These options can be combined every included option will be indicated in the part number of the unit Table 2 Option Description A Epoxy painted exterior M Gold Electrical...

Страница 14: ...hipped prepaid C Exclusion from Warranty THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS OR OTHERWISE Components manufactured...

Отзывы: