ITT neo-dyn 100p Скачать руководство пользователя страница 17

 

Enclosure 6N Pressure Switches 

Page 14

  

WARRANTY INFORMATION 

A. Warranty

ITT Industries (ITT) warrants that at the time of shipment, the products manufactured by 

ITT Neo-Dyn

®

 and sold hereunder, will be free from defects in material and 

workmanship and will conform to the specifications furnished or approved by ITT. 

B. Warranty Adjustment

If any defect within this warranty appears, the Buyer shall notify ITT immediately. 

ITT agrees to repair or furnish a replacement for, but not install, any product which, 

within one (1) year from the date of shipment by ITT shall, upon test and examination by 

ITT, prove defective within the above warranty. 

No product will be accepted for return or replacement without the written authorization 

of ITT. Upon such authorization, and in accordance with instructions by ITT, the product 

will be returned with shipping charges prepaid by the Buyer. Replacements made under 

this warranty will be shipped prepaid. 

C. Exclusion from Warranty

THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER 

EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS, OR 

OTHERWISE. 

Components manufactured by any supplier other than ITT shall bear only the warranty 

made by the manufacturer of that product, and ITT assumes no responsibility for the 

performance or reliability of the unit as a whole. 

In no event shall ITT be liable for indirect, incidental or consequential damages nor shall 

the liability of ITT arising in connection with any products sold hereunder (whether such 

liability arises from a claim based on contract, warranty, tort or otherwise) exceed the 

actual amount paid by Buyer to ITT for the products delivered hereunder. 

The warranty does not extend to any product manufactured by ITT, which has been 

subject to misuse, neglect, accident, improper installation, or to use in violation of 

instructions furnished by ITT. 

The warranty does not extend to or apply to any unit, which has been repaired or altered 

at any place other than at ITT’s factory or service locations, by persons not expressly 

approved by ITT. 

Содержание neo-dyn 100p

Страница 1: ...N MODELS 100P 110P 142P 180P 200P ADJUSTABLE PRESSURE SWITCHES MODEL 160P ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610 0010...

Страница 2: ...injury death or substantial property damage if the warning is ignored CAUTION Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored SPECIAL COND...

Страница 3: ...IGURATIONS 2 CHAPTER 2 INSTALLATION 3 MOUNTING 3 PROCESS CONNECTIONS 4 PROCESS MEDIA 4 POTENTIALLY EXPLOSIVE ATMOSPHERES HAZARDOUS LOCATIONS 5 ELECTRICAL CONNECTIONS 5 CHAPTER 3 ADJUSTMENTS AFTER INST...

Страница 4: ...e a polyimide Kapton sensing diaphragm nitrile O ring and aluminum alloy or corrosion resistant steel CRES pressure port CRES diaphragms and all welded constructions are also available in some models...

Страница 5: ...re Switches that are not covered in this manual you can contact Neo Dyn or our representatives in several ways The Neo Dyn customer service phone number is 661 295 4000 Our customer service department...

Страница 6: ...NG Do not remove switch while under pressure MOUNTING The Pressure Switch can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supp...

Страница 7: ...ipe joint sealing compound CAUTION Avoid excessive torque on all threaded connections WARNING Do not exceed the marked maximum operating pressure in normal operation WARNING Do not use as a safety dev...

Страница 8: ...tandard with a green wire grounded to the case 72 inch 183 cm leads are available as R Option and other lead lengths may be ordered as special configurations The leads are intended for installation in...

Страница 9: ...check the increasing setpoint of a pressure switch connect a pressure source and a calibrated pressure gauge or transducer to the pressure port and slowly apply increasing pressure or vacuum on Model...

Страница 10: ...Switch If application of pressure or vacuum 10 greater than the adjusted setpoint fails to produce actuation first check for contamination in the process connection and verify that the expected press...

Страница 11: ...erfaces Weight approximately 3 pounds 1 4 kg each Conduit Connection 14 NPT male Standard Pressure Port Wetted Material 1 18 NPT female Wetted Materials 4 9 14 NPT female Models 160P both ports and 18...

Страница 12: ...umber Breakdown Wetted Materials Table 1 No Description 1 Aluminum alloy port Teflon coated polyimide Kapton diaphragm and nitrile O ring 1 Aluminum alloy port and piston Teflon seal Nitrile O ring on...

Страница 13: ...06 9 5000 344 8 100P 5 6N 5 3000 206 9 5000 344 8 100P 7 6N 7 3000 206 9 5000 344 8 100P 8 6N 8 3000 206 9 5000 344 8 Pressure Ratings Model 110P Table 3 Part No Range No Max Operating Pressure psig b...

Страница 14: ...11250 776 200P18 6N 8 10000 690 15000 1034 200P18 6EN 8 9500 655 15000 1034 Pressure Ratings Model 160P Table 6 Part No Range No Max Operating Pressure psig bar Proof Pressure psig bar 160P 2 6N 2 30...

Страница 15: ...and Ambient Temperature Ratings Minimum ambient temperature is 40 C 40 F except with B Option and Kalrez O rings it is 26 C 15 F Form C6N SPDT 11 amp 125 or 250 VAC to 70 C 158 F max T5 11 amp 125 or...

Страница 16: ...erials 100P 110P 160P 180P 200P C EPR O Ring Refer to Wetted Materials 100P 110P 160P 180P 200P E 7 16 20 SAE Port Wetted Material 1 Only 100P 200P except Range 8 G 14 NPT Male Port 110P Wetted Materi...

Страница 17: ...pped prepaid C Exclusion from Warranty THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS OR OTHERWISE Components manufactured by...