Figure 30: Rotor components
6.6.8 Remove the seal-chamber cover
1.
Remove the gland stud nuts.
2.
Remove the seal-chamber stud nuts.
3.
Remove the seal chamber (161).
4.
Remove the shaft sleeve (524).
The mechanical seal is attached to the sleeve.
NOTICE:
Be careful with the mechanical seal. Carbon or ceramic components are brittle and easily bro-
ken.
5.
Remove shims from shaft (check sleeve to ensure no shims were retained after removal).
6.
Remove the rotary portion of the seal from the sleeve by loosening the setscrews and sliding it off
the sleeve.
Refer to the mechanical-seal instructions for more information.
7.
Remove the gland (452), the stationary portion of the seal, and the O-ring (412.21).
6.6 Disassembly
Model ICO i-FRAME, ICOH i-FRAME Installation, Operation, and Maintenance Manual
73