5.13 Make the final alignment of the pump and driver
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any in-
stallation or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with
all international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
•
Misalignment can cause decreased performance, equipment damage, and even cata-
strophic failure of frame-mounted units leading to serious injury. Proper alignment is
the responsibility of the installer and the user of the unit. Check the alignment of all
drive components prior to operating the unit.
•
Follow the coupling installation and operation procedures from the coupling
manufacturer.
You must check the final alignment after the pump and driver are at operating temperature. For initial
alignment instructions, see the Installation chapter.
1.
Run the unit under actual operating conditions for enough time to bring the pump, driver, and
associated system to operating temperature.
2.
Shut down the pump and the driver.
3.
Remove the coupling guard.
See Remove the coupling guard in the Maintenance chapter.
4.
Check the alignment while the unit is still hot.
See Pump-to-driver alignment in the Installation chapter.
5.
Reinstall the coupling guard.
6.
Restart the pump and driver.
5.13 Make the final alignment of the pump and driver
62
Model IC, ICI, ICH, ICIH Installation, Operation, and Maintenance Manual
Содержание Goulds Pumps IC
Страница 1: ...Installation Operation and Maintenance Manual Model IC ICI ICH ICIH ...
Страница 2: ......