5.14 Deactivate the i-ALERT
®
2 Equipment Health Monitor
NOTICE:
Always deactivate the health monitor when the pump is going to be shut down for an extended
period of time. Failure to do so will result in reduced battery life.
NOTICE:
Always reset the health monitor when the pump is started after maintenance, system change,
or being shut down for an extended period of time. Failure to do so may result in false baseline
levels that could cause the condition monitor to alert in error.
1.
To deactivate or reset the i-ALERT®2 Equipment Health Monitor, please refer to the i-ALERT®2
Equipment Health Monitor IOM or visit
http://www.ittproservices.com/aftermarket-products/monitor-
5.15 Make the final alignment of the pump and driver
WARNING:
•
Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any installa-
tion or maintenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals
(IOM) for specific instructions and recommendations.
•
Misalignment can cause decreased performance, equipment damage, and even cata-
strophic failure of frame-mounted units leading to serious injury. Proper alignment is the
responsibility of the installer and the user of the unit. Check the alignment of all drive
components prior to operating the unit.
•
Follow the coupling installation and operation procedures from the coupling manu-
facturer.
You must check the final alignment after the pump and driver are at operating temperature. For initial
alignment instructions, see the Installation chapter.
1.
Run the unit under actual operating conditions for enough time to bring the pump, driver, and asso-
ciated system to operating temperature.
2.
Shut down the pump and the driver.
3.
Remove the coupling guard.
See Remove the coupling guard in the Maintenance chapter.
4.
Check the alignment while the unit is still hot.
See Pump-to-driver alignment in the Installation chapter.
5.
Reinstall the coupling guard.
6.
Restart the pump and driver.
5.16 Doweling the pump casing
The pump casing must be doweled to the baseplate in order to maintain the proper pump position.