Symptom
Cause
Remedy
There is excessive vane-tip runout of
the impeller.
The vane is bent.
Replace the impeller.
7.4 i-ALERT
®
2 Equipment Health Monitor troubleshooting
To troubleshoot the i-ALERT
®
2 Equipment Health Monitor, please refer to the i-ALERT
®
2 Equipment
Health Monitor IOM or
https://www.ittproservices.com/Our-Services/Aftermarket-Products/Monitoring/i-
Symptom
Cause
Remedy
There are no green or red flashing LEDs.
The battery is dead.
Replace the condition monitor.
The unit is deactivated.
Activate the condition monitor.
The unit is malfunctioning.
Consult your ITT representative for
a warranty replacement.
The red LEDs are flashing, but the tempera-
ture and vibration are at acceptable levels.
The baseline is bad.
Check the temperature and vibra-
tion levels and reset the condition
monitor.
The unit is malfunctioning.
Consult your ITT representative for
a warranty replacement.
7.4 i-ALERT®2 Equipment Health Monitor troubleshooting
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
155