Commissioning, Startup, Operation, and Shutdown
Convert to oil-mist lubrication
NOTICE:
Make sure that pipe threads are clean and apply thread sealant to plugs and fittings.
You can convert from ring-oil lubrication to oil-mist lubrication in pumps with ball bearing
construction. The radial and thrust end bearing housings (134) have pre-drilled connections for
oil misting:
• 1/4 in. NPT connection on the inboard side of the housing
• 1/2 in. NPT connection on the outboard side
Purge-oil mist lubrication provides intermittent oil mist in the bearing housing. This system uses
the oil sump in the housing, and requires the oil ring and the constant-level oiler.
Pure-oil mist lubrication provides constant oil mist in the bearing housing. This system does not
use the oil sump, oil ring, or constant-level oiler. The drain connections in the bearing housing
are used as part of the oil recirculation system.
1. On the radial housing, replace the 1/4 in. NPT plug with an oil-mist fitting provided by the
oil-mist system manufacturer.
The 1/2 in. NPT connections remains plugged because it is not required in the oil-mist
system.
2. On the thrust housing, replace the 1/4 in. NPT plug with an oil-mist fitting. Replace the 1/2
in. NPT plug with a 1/2 in. to 1/4 in. bushing and insert an oil-mist fitting provided by the oil-
mist system manufacturer.
Oil-mist connections
A.
Radial and thrust (1/4 in.)
B.
Thrust only (1/2 in.)
C.
Radial and thrust drain
NOTICE:
In both housings, the inboard channel beneath the 1/4 in. NPT connection must be 1/4 in. plug-
epoxied to prevent rapid oil drainage. Drill a 1/8 in. hole for required but restricted drainage.
Lubricate the bearings after a shutdown period
1. Flush out the bearings and bearing frame with a light oil to remove contaminants.
During flushing, make sure to rotate the shaft slowly by hand.
2. Flush the bearing housing with the proper lubricating oil to ensure oil quality after cleaning.
3. Refer to "Reassembly" section for proper bearing greasing procedure.
Shaft sealing with a mechanical seal
Precautions
WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified. Prior to startup,
make sure that all areas that could leak pumped fluid to the work environment are closed.
46
Model 3610, API Type BB1 API 610 11th Edition Installation, Operation, and Maintenance Manual