Risk of serious physical injury or death from rapid depressurization. Ensure pump is iso-
lated from system and pressure is relieved before disassembling pump, removing plugs,
opening vent or drain valves, or disconnecting piping.
•
Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting
and handling and wear appropriate Personal Protective Equipment (PPE, such as steel-
toed shoes, gloves, etc.) at all times. Seek assistance if necessary.
•
Precautions must be taken to prevent physical injury. The pump may handle hazardous
and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must
be handled and disposed of in conformance with applicable environmental regulations.
CAUTION:
•
You must keep the shop area clean and free of any substances that can contaminate the
magnets, such as ferrous metals.
•
The magnets in this unit are extremely powerful. Beware of serious injury to fingers and
hands. Keep magnetic drive components and magnetic tools apart by a minimum of 1 m |
3 ft.
NOTICE:
Use a bench with a non-magnetic work surface such as wood or brass when you work on the
pump.
6.3.2 Required tools
WARNING:
This pump contains extremely strong magnets. You must use non-magnetic tools and work sur-
faces.
Tools
•
Assorted metric open-end or socket sizes 13 mm, 17 mm, 18 mm, 19 mm, and 24 mm
•
Hex wrenches, sizes 2.5 mm, 3 mm, 5 mm, and 6 mm with a 12.07 cm | 4.75 in. minimum reach
•
Hex wrench, size 8 mm with 15 cm | 6 in. minimum reach
•
Torque wrench
•
Strap wrench
•
3/8 in. eyebolt
6.3.3 Prepare the pump for disassembly
1.
Lock out power to the driver.
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or main-
tenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all in-
ternational, national, state, and local rules.
6.3 Disassembly
Model 3296 EZMAG Installation, Operation, and Maintenance Manual
57