Item Description
1.
By-pass line
2.
Shutoff valve
3.
Foot valve
4.
Check valve
5.
Discharge isolation valve
Figure 29: Pump priming with suction supply below pump with foot valve using bypass around
check valve
5.7.3 Other methods of priming the pump
You can also use these methods in order to prime the pump:
•
Prime by ejector
•
Prime by automatic priming pump
5.8 Start the pump
WARNING:
Continuous operation against a closed discharge valve can vaporize liquid. This condition can
cause an explosion due to confined vapor that is under high pressure and temperature.
WARNING:
Risk of equipment damage, seal failure and breach of containment. Ensure all flush and cool-
ing systems are operating correctly prior to starting pump.
5.8 Start the pump
50
Model 3296 EZMAG Installation, Operation, and Maintenance Manual