This example shows the XL1, XL2-S, and XL2:
108
370H
418
184
351
5.
Remove the four hex nuts (355) from the seal gland plate.
6.
Loosen the set screws on the seal drive collar and slide the sleeve out of the seal.
7.
Service according to the seal manufacturer’s instructions.
6.4.11 Remove the dynamic seal
WARNING:
Covers are heavy, use the proper support to avoid personal injury.
This procedure only applies to the 3180 and 3185 pump models.
1.
Remove box-to-backplate nuts (357J).
2.
Remove the backplate (444) by tapping on the end of the studs with soft-faced hammer.
6.4 Disassembly
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
89
Содержание GOULDS PUMPS 3180
Страница 1: ...Installation Operation and Maintenance Manual Models 3180 3181 3185 and 3186 ...
Страница 2: ......
Страница 153: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 151 ...
Страница 155: ...9 1 Certificates of conformance Models 3180 3181 3185 and 3186 Installation Operation and Maintenance Manual 153 ...