3.
Remove the O-ring (412C) from the groove and gasket (360P).
6.4.8 Impeller removal
WARNING:
Risk of severe physical injury or death from explosion of trapped liquid. Never use heat to re-
move parts unless explicitly stated in this manual.
CAUTION:
Risk of physical injury from sharp edges. Wear heavy work gloves when handling impellers.
NOTICE:
Be sure to align the pry bars with the impeller vanes in order to prevent damage to the impeller.
The pump has one of these impellers. Choose the removal procedure that applies to the impeller in the
pump:
•
Open impeller
•
Enclosed impeller
•
Shearpeller™
6.4.8.1 Remove an open impeller
1.
Secure the back pull-out assembly firmly to the workbench.
2.
Lock the shaft (122) to prevent turning.
3.
Remove the impeller nut (304) and O-ring (412A).
6.4 Disassembly
Models 3180, 3181, 3185, and 3186 Installation, Operation, and Maintenance Manual
83
Содержание GOULDS PUMPS 3180