b) If the pump is laid in a horizontal position, place a container under the pump.
c) Remove the coolant plugs and empty the coolant.
Figure 16: With a cooling jacket
Figure 17: Without a cooling jacket
Fill with coolant
Use a coolant that has a mixture of 70% water and 30% monopropylene glycol. The coolant should
prevent corrosion and be nonpoisonous (generally recognized as safe by the FDA as food additives under
part 184 and 182).
NOTICE:
Clean water with an anti-corrosive is an acceptable coolant when there is no risk of freezing.
1. Fill with coolant until it overflows through the opposite hole, as shown here.
Quantity: approximately
• 11 liters (12 US quarts) without cooling jacket
• 47 liters (50 US quarts) with cooling jacket)
Maintenance (Continued)
30
Flygt 5150.350, 5150.360 Installation, Operation, and Maintenance Manual