CANNON STANDARD
page 8 of 20
ASSEMBLY AND WIRING INSTRUCTION
CA-BAYONET IP69K
Circular Connector with Protection Class IP69K
CAS25092E
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU/FA
AKU/FA
G5820W
JPE 18.12.2018
ITT Cannon GmbH, D-71384 Weinstadt
3.4 Extraction Tools
In case a contact has to be exchanged the following extraction tools are to be used:
Extraction Tools
Description
Name
Order No.
extraction tool for contact size # 16 CET-F80-16
121086-0081
extraction tool for contact size # 12 CET-F80-12
121086-0080
extraction tool for contact size # 8
CET-8
121086-0079
extraction tool for contact size # 4
CET-4
121086-0094
extraction tool for contact size # 0
CET-0
121086-0077
ATTENTION:
A proper removing of contacts is only ensured if the required extraction tools are used.
3.5 Pipe Wrench
Soft Jaw Adjustable Pliers
order No.: 550014-1644
for tightening the endbell, housing.
3.6 Operating Instructions for Machined Contacts
1.) strip wires to lengths, for stripping details, see 4.1
2.) open hand tool and insert the contact in the crimp profile
3.) position the stripped cable in the contact
4.) press hand tool to end position
5.) open hand tool and extract the contact, check the contact visually
6.) minimum crimp tensile requirements see DIN EN 60352-2
-
there shall be no loose strands out of the crimp section
-
the contact must be crimped straight to the cable
-
deformed contacts must not be used. In this case crimp again
-
while the preparation, strands must not be hurt or cut
1
insulation of cable
2
wire
3
contact
4
inspection hole (wire strands must be visible)
loose wire strand
no wire strand visible