CANNON STANDARD
page 11 of 20
ASSEMBLY AND WIRING INSTRUCTION
CA-BAYONET IP69K
Circular Connector with Protection Class IP69K
CAS25092E
Bearbeitet:
Geprüft:
Norm:
Änd.-Stand:
Änd.-Datum:
AKU/FA
AKU/FA
G5820W
JPE 18.12.2018
ITT Cannon GmbH, D-71384 Weinstadt
Table 2: wrench size and clamping torque of coupling nut
COUPLING NUT
cable sealing area
wrench size
clamping torque
D07
16 mm
1,0 Nm ±0,2
D09
19 mm
1,3 Nm ±0,2
D11
22 mm
1,7 Nm ±0,2
D13
25 mm
2,3 Nm ±0,2
D14
27 mm
3,0 Nm ±0,2
D17
32 mm
3,0 Nm ±0,2
D19
34 mm
3,5 Nm ±0,2
D20
36 mm
3,5 Nm ±0,2
5.2 Insertion of Contacts
1
Plug on and fix the connector for assembling.
Use therefore an assembly adapter or housing.
2
Assemble socket contacts sizes 15S/16S/15/16/12 and 25
only by using guide pins, see 3.3.
Insert guide pin into contact mating side.
3
Moisten the contacts with isopropyl alcohol for easier
contact insertion.
4
Pre-insert the contacts in the insulator.
Contact insertion is started in the center of the insulator.